Replacing A Range Hood
How do I replace a range hood for an over the range microwave?
Similar Tutorials
How to Lay Sod - The Right Way!
- Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
- This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
- If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ... Similar Topics From Forums
Our new range hood states is should be a dedicated 15 amp circuit. Is okay to put it on a 20 amp or would that violate code?
I'm replacing my electric range with gas. The electric has (I think) a four-wire #6 or #8 cable approx 60ft run with a 40a dual post breaker. I say "I think" because the wire is behind everything else in the panel. I see red/white/black wires, but no ground and I can't read the jacket. Once I cut the main, i'll have a closer look.
The gas range requires only a 15amp breaker. Can I simply replace the breaker with 15A and the 4 prong outlet with a Nema 5-15p? I'd cap off both ends of the red wire. Is there some sort of code that says I need to maintain the 40A circuit for a future stove? Or is there some sort of transformer I can plug into the stove end and avoid all that hassel. ?
Morning people. I'm installing a chimney style range hood for a friend of mine and he wants me to leave the plug wire on instead of hard wiring it. This would be permanent. Reason being is so he could remove it himself at a future date to tile the wall. This means I'd have to put a receptacle on the wall next to the vertical duct and it would be hidden behind the vent stack cover. It wouldn't be easily accesable so I'm thinking that's a code violation anywhere you go. From what I found it's a grey area. Any thoughts? Thanks
I need to replace a damaged non insulated 16awg push on female connector that is for a range element. Is it necessary to only use non insulated high temp replacements?
I live in an older house and the range hood over the stove came loose and fell off the wall last night. The wires are now exposed and I don't know what to do with them. There are three wires. I can post a pic if needed. Also when I cap them off should the shut down the main power to the house? I've never done this kind of thing before.
We've put in a new 240v line for the range. My question is- for the rough inspection should this line be connected to the breaker or no?
I'm upgrading the range oven circuits in my property, so I'll need about 150' of 6-3. The cost is almost prohibitive though. Anyone know of any good buys on this stuff?
Hi all, this is my first post, so...my kitchen was just renovated and the electrical outlets are on the walls and I wanted them in plugmold under the cabinet. Why didn't it happen? Long story, but I'm doing it myself now. The electrical receptacles are on 2 separate circuits with a gfci receptacle on each and neither circuit has a receptacle outside the kitchen where I can put the gfci's, so I'm putting gfci breakers in the panel instead. I've run into a different problem on each circuit that'd like some advice on.
Circuit 1: this is a 20 amp circuit. I have to plug this circuit's neutral wire into the gfci breaker, but I couldn't see which neutral wire matched the hot wire (buried in mess of wires) and I don't have a continuity tester so I just pulled one neutral at a time (tedious) until the circuit failed, but it never failed. So I did this again for every neutral...same result. This circuit shares a few boxes with other circuits so I'm wondering if the neutrals on different circuits are tied together somewhere, and if so I'm pretty sure, but not completely, that that's not going to work with the gfci breaker. So I didn't install that gfci breaker since I'm not confident it would actually gfci (yep i verbified gfci). What do you think? Circuit 2: this is a 20 amp circuit. This circuit currently has the refrigerator, gas stove and range hood, and then a gfci in front of 3 electrical receptacles, which already sounds bad since I thought the kitchen receptacles required 2 dedicated circuits. I replaced that breaker with no problem, but it tripped after a few minutes and continued to trip every few minutes. I haven't changed anything else on that circuit yet and it's never tripped before, but now it is, so I put the old breaker back for now. The current gfci receptacle is only protecting the 3 outlets since the appliances are ahead of it. I know you wouldn't normally want the appliances gfci protected, so do you think the refrigerator motor may be a problem? Do I need the appliances on a separate circuit? What would you suggest I do? Thanks, and if you're wondering "why all the effort?", it's partly because I'm meddlesome, partly because I'm bored, and partly because the backsplash tile is to be on showcase, not the electrical receptacles.
I was going to put this in this thread Junction box in stud wall behind drywall? but, decided to start a new one.
Two nights ago while sitting in my kitchen the can lights in my soffits above my cabinets suddenly went out. At first I thought my daughter or her boyfriend was messing with me and reached around the corner and flipped the switch. Nope. Tried the other switch near me and nothing. Everything else in the kitchen worked. Thinking tripped breaker for a moment...nope other lights work on the circuit. Can't be 6 CFL's burnd out at the same time. Hmmmmm? Background: Kitchen was remodeled 12 years ago. Drywall was in good shape so not removed. Added circuits for Fridge, Microwave, Garbage disposal, Stove (gas),Dishwasher, range hood, and countertop recepts. None of these are tied to lights. Original task lighting was 4' tubes over countertops above cabinets. Remodel added sofits and can lights from these two feeds Started tracing circuit path to look for loose/broken wire. Found no power at lights. Checked power at breaker...Good. Follow wire to kitchen, no junctions. Wire disapears up into wall below the switch area. Check for power at switch box. Yep, power there. Power off and pigtail Neutral/hot wires at a can light together. No continuity on the load side of the switch circuit. Broken wire somewhere between the switch and the lights. Fortunaly there is an attic space above the kitchen. Unfortunatly, it is a short headroom ~3' or less and full of blown ihn insulation. In I go to trace the wire. after about 10 min up there I found the burried junction box. At some time in the past there used to be a single light in the center of the "U" shaped kitchen cabinets. This was abandoned and the box was drywalled over...still in the location for the light hookup so the cover was not readily accessable. found a tightly twisted Ground, Neutral and Hot with nuts. All looked good untill I Started messing with them. found that one of the hot leads had broken right at the insulation on the wire. Looking at it closer I could see some arc burn at the break. I am thinking that when the handy hack that did the job nicked the wire he did not know or care and tristed it together anyway. It took over, to my best guess, 20 years for it to fail. Moral... It can happen
I dropped a teeny tiny screw holding the metal housing of one of the lights in the exhaust hood over the cook top. It went right down the back of the oven and it's lost. How can i replace it?
|