Can I Install European Light Switch On Na System?
I admit, I'm jealous of the European style light switches, with the little white buttons instead of the standard switches they have here in Canada. I don't know much about the design of the European wall switches, other than they are designed for 250v 10a systems. And that I can buy them on eBay! So I am wondering if anyone can tell me whether it might be possible for me to install the European 250v light switches on a North American 120v system?
Similar Tutorials
How to Lay Sod - The Right Way!
- Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
- This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
- If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ... Similar Topics From Forums
Hello -
I'm attempting to install a new bathroom vent fan / light combo. I pulled out the old one from the ceiling and am ready to install the new one. I'm not sure how to wire up the new one. The wire coming from the 2 Switches/Wall has the following 4 wires: Black, White, Red, Bare Copper Ground The wires coming from the Light/Fan Unit a Light: Black, White, Red Fan: Black, White Fan/Light Housing: Green Ground Wire Any help would be appreciated. Thanks!
Im replacing what I thought was 2 single pole light switches but there is 3 black wires and one red. I hooked them up to the new switches but both switches worked the one light can anyone tell me how to connect the wiring?
updating an older home (1927) and would like to replace all the receptacles/switches/plates with newer Lutron style white switches, where is the best place to order these or pick them up? Not sure if its worth shopping online or if the big box convenience negates cost difference?
Thanks!
When repairing a light switch I came across this wiring in a supposed 3-way setting in my kitchen. Two Single Pole Double Throw switches controlling a single light fixture.
Check out the quick and dirty wiring diagram showing the way these are connected. I believe there should be a 14/3 between the two switches right? All I see is 14/2 coming in and a 14/2 going across to the other switch, and then a 14/2 going to the light. And why are the neutrals cut and wire capped? This doesn't make sense to me, but the light does work from both switches. Any insight will be greatly appreciated. Cheers!
Scratching my head on this. New pole building. For now, I want to use one circuit for the lights. What I'm trying to do, is, at one door, I have a 3 way, switching two flourescent lights. Also in that 4-gang light switch, is run a light over the door on the outside, and a light over the overhead service door, and another light over the door, on the inside. So 1 3way, and three single pole switches. At the back door, the other 3 way for the same two lights, and a light over the door on the outside, and another light over the door on the inside. I have the power from the m/p, going into the light box nearest the M/P. Long story short, instead of how I have it, which operates all the lights, as long as one of the three ways are on. If someone could help me with how it should be. I am using 12-3 from the switches. Using 12-2 from the first light box, to the second. I have a another 12-2 running into each switch box, to supply power for the single pole switches.
Thanks for any/all input.
I am replacing the fan in one of our guest bedrooms and thought it would also be a good time to replace the switch. Currently there is one switch to turn the fan and light on/off.
I'd like to put the fan and light on two separate switches. It appears that 12/3 or 14/3 is already in place (white, black and red/pink wires in switch enclosure w/ bare copper for ground). I'd also like to make the light dimmable and the fan speed adjustable from these switches. Could anyone recommend a good switch(es) to accomplish this?
Hello everyone,
I am trying to replace a 40-year old garage door opener that stopped working, and the motor reads "250v"-- are 250 volt openers standard? does the 250v mean something completely different? or will I have to re-wire it to a standard 110v outlet type to put in a new opener? The original cover has most likely been lost to time; the brand was Overhead Door company. I haven't purchased any new openers yet, making sure I know what I am getting into first :-) The door is not especially large --9'x7' not sure of their weight; if it matters, the door will likely be replaced shortly as well. Thanks for any and all help!
I have two 3-way switches in my master bath that have never worked properly. The house is very old and has been worked on over the years by many different people with greatly varying levels of skill. I was finally fed up with these switches and tried to fix them. I tried to follow instructions I found online, so with the power off I disconnected all the wires from both switches, then turned the power back on and used my volt-meter to discover which wire was hot. It turned out to the a red wire at switch #1. The other two wires are white and black (and yes, there also is a ground). I connected this hot wire to the darkest screw, connected the white and black to the other two screws and tried to test for continuity at the other switch. I couldn't get a reading on any of the wires at the other end. I tried turning the power back on and testing to see which wire was now hot at the second switch. It was the white wire, so I attached that to the darkest terminal, and attached the red and black to the other two terminals. The switches don't work any better than they did before I started - that is, both switches have to be turned on for the light to come on. What is my problem here? Thank you!
i have 3 switch sets in my house that are giving me absolute fits.
#1 kitchen switch, controls the light over the outside door Code: 3 sets of lines coming in, i cannot get this 3 line to work without tripping the breaker every time i turn the switch off #2 bathroom switches Code: power feed line same issue as the first set, flip the switch and trip the breaker (different breaker from the kitchen switch) #3 living room switch and plug controlled via switch Code: power feed line flip switch, trip breaker the switches i have are "1 pole" am i using the wrong switches for this job?
Hi All,
Need to replace an old faulty two switch fixture in the bathroom (light and exhaust fan). Right now, each switch on the single fixture separately operates either the light or the fan, regardless of the position of the other switch. Want to keep things that way. Here is a picture of the old fixture's wiring: http://dl.dropbox.com/u/1179096/photo1.jpg To replace this fixture, I bought to the Leviton 5634 (design diagram he http://communities.leviton.com/servl...224%205634.pdf) Unfortunately, what is confusing me is the the different designs between the two fixtures and the fact that the original unit seems to have some kind of patch or cross over type wire connecting the top and the bottom switches (see photo link above). Any help/advice on how to wire this new fixture based on the picture of the current wiring configuration would be greatly appreciated. Thank you!!! |