Ceiling Fan Hum

I installed 3 ceiling fans today, with the help of an electrician friend.  Two are Hampton Bay and one is westinghouse.  I am also using Lutron Maestro dimmer wall switches.  One of the Hampton Bay and the Westinghouse have developed apulsing hum when the fan is on.  Interestingly, one HB does not.



In the instruction manuals for both brands, it says that it takes 24 hours for most noises to go away.  However, it also says that I should not have used a solid state variable speed control.



I really hate the thought of having to take these down.  Any advice?
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I am putting up two ceiling fans in my garage.  They come with wall mount controls and the instructions specifically say do not wire two fans to one switch so I am going to wire the fans to their own switches.  My question now is how to wire the two witches to one breaker.  I have room in my panel for two breakers but I don't think that's necessary.



Thanks!
      
After my electrical panel was replaced I noticed that my ceiling fan light was dim.  My fan works fine on all speeds but the light is dim.  It is a Hampton Bay model MKV with a remote control.  Wondering if it could be a relay problem with the unit??
      
I've had an on-off problems with two of my ceiling fans (different makers, one hunter and one minka). Wired differently too, the minka one is controlled by a wall remote control, and the hunter one by two wired wall switches).



Every now and then, for no reason, the fan will stop working. It may stop working for a day, a week, whatever.. then start working again for a month or even a year. When this happens, the light kit on both fans still works (on the minka, the light kit and fan are on the same line, separated in the fan by the remote control receiver. On the hunter, it's two different wires going into the fan.).



It stumps me.. I'll just turn the fan on one day, it will spin a little bit, then stop. Nothing gets it to work. I can hear a small hum in its motor, like it's getting power, but it won't spin. Then a week later I may accidentally turn it on again and it will run. Two and three years ago I had repeated on/off problems with both fans. Last year, both worked perfectly the entire year. This year one of them has started acting up again.



Any hints would be appreciated.
      
I am currently remodeling a bedroom in my home for a new baby.  I have gutted the room and am replacing all the electrical and adding new recessed lighting.  The room will also have a ceiling fan, along with the recessed lighting.  I am looking for a single gang light switch that will operate the ceiling fan independently of the recessed lighting, with a dimmer for the recessed lighting.  I don't have room for a double gang box where the switch is currently placed, as there is a closet in the way.  Is there such a thing as a switch that will operate the ceiling fan and it's lighting on a normal on/off switch, with a dimmer that can independently control the recessed lighting?  I have checked with the local big box stores and everyone has told me I will have to run two switches.  Is this the case?  Any info would be greatly appreciated.  Thanks in advance.
      
Hello,



I took a shot at installing a ceiling fan for the first time and I would like to get advice if I did the wiring correctly. There were Black, Copper, Red, and White Wires coming from the ceiling. I read the instructions and connected the wires as stated on the manual. I was left with the Red wire. I called a friend up and he told me to connect the Red wires from ceiling to the Black Connections from Ceiling and Fan. The fan works but something is irking me inside thats telling me this is not safe. Could anyone with any know how in this subject guide me in the right direction?
      
I replaced a ceiling light with a fan/light with a remote. everthing works. their is one light switch and one dimmer switch. The dimmer switch has a red wire and a black wire connected to the black wires coming out of the dimmer switch, plus a green wire hooked to the metal portion of the dimmer. My question is: Do I have to remove the dimmer switch, if so, can I disconnect the red and black and hook them together? If I have to replace the dimmer with a regular switch, what kind of switch do I get?

Thank you
      
I've installed two dimmer switches in the bar area of my basement. It's the dial type, where you can push the dial in to turn the light on or off, or turn the dial to dim the light. One dimmer operates the recessed lights in the ceiling, and the other dimmer switch works a pendant light that I have over my bar. The dimmer for the recessed lights works totally fine. They turn on, off and dim. The pendant lights, on the other hand, only turn on and off. They for some reason will not dim. I checked the voltage on the pendants to see if maybe it was an issue of the switch being a high voltage dimmer operating low voltage pendants, and the pendants are 120V with 75 max wattage. I'm at a stand still. I have no idea what I'm doing wrong. Do any of you have suggestions? I took a couple pictures, not sure what good they'll do. The best I can do for a camera is my iPhone, so they're not the best quality.








      
I'm trying to fix a problem with a track light installment over the a bar I've just put in. I've done it before. never had issues. but this particular problem is driving me nuts. It just defies logic.  The electrician who actually installed the associated dimmer switches with this dining room area was called as it seems it may be a flaw with his wiring, but he's blown us off and I have to try and solve this myself.



This is how it's all set up. I've been rehabbing our home from top to bottom, and converted our old kitchen into a dining area. Within this dining area are four sets of lights, all controlled from one box containing four dimmer switches. I set up all the new wiring and installation of the lights in the ceiling, and we paid an electrician to come in, check everything out, set up the multiple switches, and connect it all to the board. It's all new copper wiring from beginning to end, as I didn't want to connect or splice in to the old aluminum wiring that was in place. All the new wiring and lights are on a dedicated 15 amp breaker. Three of the sets of lights were set up to be available from the day the electrician came around. The fourth, for the track light over the bar, was left hanging from the ceiling capped off and with the switch off, as I still had work to do installing an overhead wine rack, under which the track was going to be set.



Two days ago I finally got around to putting the track up, but after setting it in place and connecting the power up the lights wouldn't work. I took the lights out to our kitchen, where I installed another track light system some time ago, plugged one of the lights in, and it worked just fine. I then went back to the bar area and used a spare track, then a spare connector, to see if I could isolate the fault, yet neither of the items provided a solution. Now here's the weird bit - every time I tried checking the system out, I'd get 120 volts showing from the wiring and from the track when I'd test with the multimeter. But the second I'd put a light into the track, the multimeter would drop to zero on the voltage reading on either the wiring or the track. Take the light fixture back out, and the voltage would pop back up. Inserting the light was thus completing some kind of odd loop. It wasn't just one light - I double checked by grabbing working lights from the kitchen track and inserting them into the other track - the same problem would pop up. Finally, having come to the conclusion that there was nothing wrong with the track at all, I took the whole assembly over to a nearby wall outlet, used some spare electric cable to connect up to the appropriate slots - presto, the light came on! I even double checked all this by grabbing another light fixture destined for our bathroom, and tried connecting it to the wiring over the bar. Nothing. Yet as with the track light, the minute I took it over to the wall outlet and connected it, the light worked.



So everything logically points to the fact it has to be something to do with this individual circuit, right, because a) the light fixtures work when plugged into another circuit and b) the other three dimmers and lights hooked up in the same box work fine and draw power from the same wire cable/breaker combination. The only things left that I can think of is that the electrician has either wired the dimmer switch up incorrectly or that there's some kind of flaw inside the switch itself. Does this make sense?



A friend also told me to double-check to make sure that the black wire feeding power to the light was indeed the hot wire, and it is.  If I touch it with the black test lead from the multimeter and put the red one to the neutral I show 120 volts. If I keep the black test lead on the black wire and put the red test lead to the ground - I also show 120 volts.



A final point. I know I'm not overloading the circuit - not even close. With all four dimmers maxed and every light on - including the test light on the track - I'd only be drawing 8 amps on a 15 amp breaker, besides which I'm only using one set of lights while I'm working on this problem anyway. This is a dedicated circuit, so there's no additional power being drawn away by something else.



So how am I getting 120 volts from this wiring, according to my multimeter, yet it won't light up ANYTHING and keeps giving off the indication that some kind of loop or short is being created every time I actually plug a light into the track? It's got me totally stumped.



Anyone have any ideas?
      
Help!  We decided to raise the ceiling in our kitchen for some new taller cabinets. We have 30" cabinets with a 7' drop ceiling. By taking out the drop ceiling we can go to an 8' ceiling with 36" cabinets.  We just had the ceiling taken out and now I see I got a problem!



This is a 2 story home, the wall in question is a load bearing wall (runs through the center of the house) The main breaker panel is in this wall (the panel opening is in the adjacent family room)



As you can see in the photos I cannot extend the wall up because all of the home wiring is in the way!  I expected I might have to run longer wires but not this. 



Some ideas we've thought about...

notch the double 2x4s (not sure how much I need to notch or allowed to)



build a cove (box) and leave the wires like they are (might be an eyesore in our new kitchen)



put up a large crown moulding along the entire wall (would be the only crown moulding in the house)



extend the ceiling up 6-7" instead of 12" (should leave enough room for wire to stay)



I'm leaning to the notching option if I can find a way to reinforce that section.



Any ideas?



thanks!
      
I have 3 bedrooms on 15 amp circuits, 14 gauge wire. Original wiring is one bedroom is on one circuit and the other 2 bedrooms on another circuit. The wall switches in each switched the top half of an outlet in each room. I converted the wire at the wall switch to a 110V feed from the outlet and ran 14/3 from the switch to the ceiling for a ceiling fan. I replaced the outlets since the jumper was cut to isolate the 2 plug ins for switching. Is this whole scenario code compliant?