Test And Find Hidden Romex Help

In my older home i just founf out that all the upstairs ( 2 bedrooms) outlets are installed on the same 20 amp circuit breaker for my kitchen. which might be a reason that when too many things are running this breaker trips. My question is I want to add a 15 amp breaker and isolate all the upstairs on this breaker so the kitchen stays seperate. i Found the romex that is installed to a downstairs outlet that is connected to all the other outlets upstairs but since it is hidden in the walls and i narrowed it down to 3 possiblities upstairs, but i am not sure. How can i test to see which one of the romex wires it could be so i can attach my new romex from the new breaker and just abandon the old wire all together.

PS. when i disconnnect the romex from the outlet downstairs in the kitchen all the outlets upstairs stop working, that is how i know that is the one that brings the electriity upstairs.
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I have an older home and i wanted to add a new 15 amp breaker for a circuit for the outlets for my upstairs. I noticed that the existing old black romex runs from the circuit breaker in electrical conduit in my walls. There is no way i can get more romex through that conduit. Can i add the romex outside the electrical conduit? i am not really sure why they ran through the conduit to begin with.
      
I have a circuit that is for 2 of the bedrooms upstairs then also runs downstairs to what used to be a garage but I am now looking to refinish as a finished area.  the circuit goes to 3 light fixtures from a switch in the unfinished room and I want to cut it off and run a new circuit for recessed lights in that area.  I dont know where the original wire comes from upstairs, does it matter if I just wire nut it in the unfinished room and leave it as a junction box?
      
I am remodeling my basement and I have a dilema with the wiring. Upstairs I have a switch that can turn on/off the basement lights. Downstairs i currently have a switch that can turn off/on the lights, I guess they both are 3 way switches.



My problem is that I want to install two different zones of dim-able lighting downstairs, but want the upstairs light-switch to turn on both zones. Once downstairs I can have the option of dimming each zone.



How would I go about wiring this?
      
Going through a crazy heat wave here in SoCal, and one of my tenants called to tell me that the electricity isn't on in some of his rooms. He turned on his portable AC unit that he has been using all summer and something may have happened.



Downstairs:The dining room light switch, downstairs light switch do not work. All outlets around them do work though, which is odd cause I would have thought they'd be on the same circuit.



Upstairs: The side bathroom light switch does not work, but outlets all work. In the master bedroom (where the AC unit is located), the master bathroom light switch does not work, nor does the master bedroom light switch. All of the outlets do not work either. I used my outlet tester and it gave me the hot/ground reversed lights. I think this means that the white/black wires are reversed on the outlets (has not changed recently).



I went over, checked all of the breakers. Switched them to off, then back on, did not fix the issue. All breakers stay in the on position without tripping, so no shorts?



Checked all GFCI's, hit test, then reset, did not solve the problem.



We unplugged everything from all outlets, and retried, but it didn't work.



I checked continuity between the main power lines, and the output of the circuit breakers, and all were fine. I did NOT check the voltages though, and will do so in the morning when I stop by again.



Is there anything else I should check?
      
I'm currently working on a house built in the 1930's. The electrical is a mess with a combination of a switch panel  and a fuse box with most of it still being knob and tube. I'm running a new electrical line to the air handler in the basement. This is due to it currently being tapped off a light circuit which also feeds an outlet in the kitchen, a bedroom, and half the outlets upstairs. (There's no rhyme or reason to the current electrical setup). 



  My main question is I'm running  12NM through bored holes in the studs to the air handler. Once I get to the handler and run it down to where it enters the appliance and switch box will I run in to codes problems. Should this run in the basement be inside a conduit or is NM cable okay? 

  Any guidance would be appreciated. 
      
So we just bought a circal-1930s house, and one very large project looming is redoing the eletrical. The house has a mix of BX, cotton-wraped romex, and some very cracked romex running around the house. combine that with some very odd additions for outlets, bad light switch placement, it's just going to be a large project.



My father in law, a licensed electrician, has promised to do the rewiring of the house this summer. The problem is I plan to do some major renovations in the coming years (namely the kitchen).



I am already drawing up floor plans now so I can stategically think of where to put needed outlets, but should they be installed at this time? Is it worth the headache to install new outlets now and put them in their proper locations when the reno comes?
      
QUESTION:  can I run (2) 14-2 romex wires in (1) 3/4 BX Armored cable?



SETUP: I am finishing my basement and a few main floor circuits are intermingled with the basement lights and outlets.  In finishing the basement, all basement electrical will be on its own circuit. Therefore, I need to rewire some main floor items.



For instance, the main floor living room outlets go through the den area below in the basement. The 3/4 BX cable goes through the ceiling to the outlets.



PLAN:  I plan to cut the armored cable shortly after it comes out of the ceiling (main floor floor) and just connect the first floor outlets in a series using the proper bushing and BX cable ends. I will strap the BX cable ends down and the romex as soon as it comes out.



The electrical inspector already gave me thumbs up on doing this for the electric oven and cooktop (bigger wires of course).



I searched and couldn't find anything to this specific question.



Any input?



B
      
I was cleaning my garage and think I got some water into an outlet. This caused 2 gfi outlets to trip, a regular outlet to stop working, and one side of a double pole circuit breaker to trip. Now the gfi's can't be reset by pressing the button, and the breaker can't be turned back on either. Does the breaker need to be shut off in order to reset the outlets? It's been like this for 3 months now. Please help!
      
We are just beginning to start with our kitchen remodel. Today, I mapped out all the circuits and this is what I found.



Circuit # 7 - 20 amp circuit to 1 back splash outlet then to 3 kitchen wall outlets, then to a closet outlet and closet ceiling light and then to a side  porch light!



Circuit # 8 - 20 amp to Dishwasher and Disposal



Circuit # 9 - 20 amp circuit to microwave and kitchen ceiling lights. 2 patio recessed lights and dining room ceiling light.



Circuit # 12 - 20 amp circuit to another back splash outlet then to 2 dining room wall outlets.



Circuit # 14 - 20 amp to Refrigerator only



Circuit # 18 - 15 amp to GFCI outlet in garage then that feeds 3 outlets for 3 bathroom outlets and 1 outside patio outlet.



I going to have to add 1 more back splash outlet due to increase in counter space. I'll put the microwave on a dedicated circuit. So I need 2 additional breakers but I only have 1 blank spot in the breaker panel. I guess I can add one of those slim tandem breakers.



So my question, is it ok to have additional wall outlets on the same circuit as a back splash outlet?  If it's ok I'll lighten up circuit # 7 by putting some of those wall outlets on the additional back splash outlet.

Oh, I have 2 20 amp circuits I did not get identified yet! I'll get to those tomorrow.



thanks!
      
I want to run Romex from a j-box, that is in the ceiling of my basement, to the main panel.  I know that I can run Romex from the box along the face of the joist (not the bottom), but what are my options once the Romex gets to the wall?  The joist I am using, conveniently enough, meets the wall ideally for where the panel is.  However, I've read that I need to run the Romex through EMT, or some form of conduit.



If you look at the picture I've attached, the panel is mounted on a piece of plywood that extends out underneath the joist.  Can I just staple the Romex to the plywood and then run it into the panel without using any conduit?  The cast iron pipe makes using any conduit quite a problem.



The cable you see is MC Lite, but I want to replace it with Romex.  There are going to be up to 9 more lines coming into the panel this very way.