Outlet In Closet

I want to put an outlet in a closet for a plug in transformer for the alarm control box in the closet. Is the outlet in the closet permitted by code?
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

With a hard wired LED closet light fixture, can it be wired like an undercabinet fixture? clamp the wire to the light and push the excess wire into the ceiling?

 

Or can i install an outlet on the ceiling and use the plug in style lights?

 

Im going to install a switch outside of the closet so there will be 1 wire going to the light.



What is the best way to do this?
      
Hey guys and gals,



got a very odd dilemma, in my dining room there is a chandelier lamp that is controlled through a dimmer switch(even though it is not a dimmer). There is also a closet with a light switch as well.



The odd circumstance i am having is when the closet light is on(via its own switch), and you turn on the dinning room light, the closet light goes out. Then if you turn the dining room light off,the closet light turns back on.



The closest light switch has zero effect on the dining room light, the dining room light seems to have control over the closet light and dining room light.



Any ideas on a fix. I was thing just replacing the dimmer(once again does not actually dim) with a single pole interrupter. I just dont want to burn my house down
      
We are just beginning to start with our kitchen remodel. Today, I mapped out all the circuits and this is what I found.



Circuit # 7 - 20 amp circuit to 1 back splash outlet then to 3 kitchen wall outlets, then to a closet outlet and closet ceiling light and then to a side  porch light!



Circuit # 8 - 20 amp to Dishwasher and Disposal



Circuit # 9 - 20 amp circuit to microwave and kitchen ceiling lights. 2 patio recessed lights and dining room ceiling light.



Circuit # 12 - 20 amp circuit to another back splash outlet then to 2 dining room wall outlets.



Circuit # 14 - 20 amp to Refrigerator only



Circuit # 18 - 15 amp to GFCI outlet in garage then that feeds 3 outlets for 3 bathroom outlets and 1 outside patio outlet.



I going to have to add 1 more back splash outlet due to increase in counter space. I'll put the microwave on a dedicated circuit. So I need 2 additional breakers but I only have 1 blank spot in the breaker panel. I guess I can add one of those slim tandem breakers.



So my question, is it ok to have additional wall outlets on the same circuit as a back splash outlet?  If it's ok I'll lighten up circuit # 7 by putting some of those wall outlets on the additional back splash outlet.

Oh, I have 2 20 amp circuits I did not get identified yet! I'll get to those tomorrow.



thanks!
      
I am working on fixing an issue with the wiring in one of the bedrooms in my older mountain home. Though I was not present for the cause of the problem, here is what was told to me by the tennant.  he claimed that he went to turn on the light in the closet, (a 3 lamp track bar light, wired to a switch) he heard a loud pop from the light in the closet and lost power to to the room. The room has 6 recessed ceiling lights on 2 separate switches, presently only half of the lights work.There are no breakers tripped, no obvious shorts at outlets. I have opened the drywall following the wires around hoping to find a short but I have found nothing. I decided to try something, and I bridged the working switch to a dead outlet and everything turned on. I am waiting til the daytime to follow the wires outside to the breaker box, but so far no breaks or anything.. curious if anyone has any pointers.. could the pop he heard from the track lighting have killed a breaker? its about the only thing left.
      
i am rewiring a bedroom. the wall with the window is 10'ish. on the right side of the window = between window and corner, will be an outlet.

the left side of the window. there is a closet door, on the left wall,  that opens to be  flush with the window wall. so no furniture can be put there. should i put an outlet there anyway ?
      
We recently purchased an apartment complex built in 1950. Inspector's report advised us to upgrade the main electrical panel (fuse box) on the  outside of the building. He also advised us to relocate fuse boxes in closets stating it is unsafe and a fire hazard.

We met with several electricians to get a quote. It's so confusing because everybody says different things... 



FUSE BOXES IN THE CLOSET: One electrician advised us to flip the panel into the bathroom(closet is adjacent to bathroom) and install a breaker instead of a fuse box, another electrician claimed it's not up to code to have breakers in the bathroom.



MAIN PANEL OUTSIDE THE BUILDING: One electrician advised us to upgrade the amperage (currently 30 amps), the other claimed it's an unnecessary change that drives the cost up since we do not have any appliances that require high amperage: no washers or dryers.

So confusing. I want the property to be SAFE for our tenants, but cost-efficient for us. Any thoughts?

thank you.
      
We just got a used hot tub.  It ran fine where we purchased it but since we got it home, it has not run.  We installed a new breaker for the hot tub and an GFCI outlet outside.  The hot tub inself has a GFCI installed on it.  If we plug it into the GFCI outlet it runs for a few seconds and either trips the circuit inside or the hot tub.  Is it necessary to have a GFCI outlet outisde if the hot tub has one?  We are thinking that this may be our problem..redundancy.  Can we install a regular outlet outside instead of the GFCI outlet?  When we plug it into a regular outlet it runs.  We want to make sure that this is safe before proceeding.
      
I'm trying to figure out how exactly this should be redone... right now there is a NM cable going from the panel though the rim joist and outside straight down into the ground and out about 2 ft into the sump well then it jus dangles there with a female plug end connected to that which the sump pump then plugs into... well this actually shorted out the other night and created a wonderful noise and sparks...



how should I redo this? right now its not even GFIC... just straight into a 20 amp breaker...



I was thinking put an outside receptical on the side of the house run that straight thorugh the back of it into the rim joist and to the panel... have the outlet on that a GFIC outlet then run a underground line from that to the pump using UF cable with a similar female plug end inside the well (the well is about 11 ft deep and the plug is about 1 ft from the top right now... then that would just plug into the GFIC outlet on the side of the house... that outlet would of course have one of those clear enclosures around it that is water tight...



suggestions? comments? code violations?
      
I have a 50 foot hdmi cable that is hooked to my TV, run through my wall to my basement then over and upto a closet where the cable is hooked to my surround sound. Unfortunately my basement ceiling is finished in drywall and there is no access to replace the cord. To make a long story short a cable TV provider came to my house to change out a box and broke the prongs on the hdmi cable. My question is, can HDMI ends be spliced or replaced somehow without replacing the whole cable.
      
I am currently remodeling a bedroom in my home for a new baby.  I have gutted the room and am replacing all the electrical and adding new recessed lighting.  The room will also have a ceiling fan, along with the recessed lighting.  I am looking for a single gang light switch that will operate the ceiling fan independently of the recessed lighting, with a dimmer for the recessed lighting.  I don't have room for a double gang box where the switch is currently placed, as there is a closet in the way.  Is there such a thing as a switch that will operate the ceiling fan and it's lighting on a normal on/off switch, with a dimmer that can independently control the recessed lighting?  I have checked with the local big box stores and everyone has told me I will have to run two switches.  Is this the case?  Any info would be greatly appreciated.  Thanks in advance.