? About Lug On Pump Of Jetted Tub!

Does the bonding lug on pump motor of jetted tub only have to be used if water lines are copper or metal? If CPVC water lines is there a need to bond and if so how?
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Hello,

We're installing a steam shower unit & need to run new electrical wiring.  We have a few questions & hope someone can help!



We have three power cords (water pump, heat pump, steam generator) & none of them currently have plugs.  The specs are as follows:  3000W steam generator 110v - 30 amp GFCI breaker, 12 v lighting, 1.2 hp water pump 110 v - 30 amp GFCI breaker, & a 1500W heat pump 110v 12.5 amps.  It says you can run the heat pump off the same circuit as the rest of the unit.



Ok, so.. we're wondering what the easiest & cheapest way of going about this is.  We want it to be SAFE first & foremost, but also want to keep expense at a minimum.



Thank you for any advice you have!




      
HI all,



I have a rain barrel system with a pump (110v) and I ran a 3way switch to my patio and one by the pump (in a shed).  My wife now wants the pump on a timer (to water the garden).



So...I could just add a timer to the switched outlet, but I want to be able to override the timer with the switch (at the patio or shed), without interfering with the pump timer operation.



I've drawn up a diagram showing my proposed setup.



Question: can I rig up the pump with two power cords and plug one into the timed outlet and one into the switched outlet and not burn down my shed in the process?




      
OK, I'm an electrical dummy ...



I have finished basement w/a bathroom. We have an ejector pump off the bathroom that has been plugged into an outlet w/gfi since I've owned the house (10 years). There is also a booster fan for my electric dryer plugged into the outlet (has been the same for 10 years).  The only thing that has ever tripped up that outlet is using a hair buzzer in another outlet within the bathroom (but once you hit the reset its fine).

   

  This morning I realize the ejector pump was not sucking down the water from the drains. I looked at the outlet and realized it needed to be reset. When I reset it, the pump would run for a few seconds and the outlet would trip up again. Tried this a few times. Thought maybe it was an issue w/the outlet altogether. Neighbor suggested maybe it was an issue with the pump. Went thru various scenarios and bottom line is when I plug the pump into other outlets it works totally fine and once I do that and reset the outlet it was on, the booster fan works fine and the outlet does not trip. So, basically this outlet is tripping when the pump is on it but the pump is not tripping other outlets and the outlet works fine as long as the pump is not on it.

   

  What could be causing this? Why would an outlet that housed the two things on it all of a sudden continue to trip when the pump is on it but the pump is fine on its own in another outlet and the outlet is fine on its own w/o the pump?
      
I am new to the forum so kindly bear with me.  I live in Mesa, AZ and have just had a PEX repipe done to bypass my copper hot water lines.  (God don't ask!  A real problem here with slab foundations.  I already had my kitchen jack hammered once.  It is NOT pretty!).

It seems really odd to me that just because it is a dedicated circuit  that code would not require that circuit to be GFCI protected.

I have a dedicated 20 amp duplex 12 AWG wire outlet under the sink and it is within a few inches of the water lines.  The outlet serves a switch for the garbage disposal and serves my dishwasher which is always hot. 

  Now that I have all my maple cabinets pulled out I thought I might change the outlet to a GFCI just to be safe.  I have a ground wire, a red wire, a black wire and a white wire.  As it is dedicated I think I should use the LINE sided instead of the LOAD side but I am not sure where the wires should go.

Could someone give me info on this?  It would be greatly appreciated.  Thank you.
      
Helicopter flies inches from LIVE electrical power lines so daredevil repairman can fix them



    But because the power lines serve  400,000 people, the line cannot be closed down, meaning the work needs  to be done while the line is live. 



   Highlighting  the dangers of the work, the commentator on the film says: 'These lines  are still energised; we are flying right at them in a big hunk of  metal filled with jet fuel.'



Read mo     http://www.dailymail.co.uk/news/arti...#ixzz1spBXQymz
      
I had a previous thread about bonding my inground pool. I had it done yesterday. I set up all the plumbing for my filter and I am going to wire it up tomorrow.

This pump was wired up once before and it is being moved. All the wiring was removed when the contractors were breaking up the concrete. It has a 25 amp breaker that I am going to replace with a GFI 25 amp breaker. I am going to wire it from the breaker box to a switch (1 foot from the box) to the receptacle about 45 feet away. I am going to use 12 gauge solid wire. I am not sure which would be better. Should I use 12/3 romex and use one as the ground or use 3 separate wires colored white, black and green. Also they had the green wire going to the ground bar in the breaker box. I guess I will attach the green(ground) wire to the ground bar and then run it to the green lugs on each receptacle.  Also which types of boxes would be best to use metal or plastic. I am going to be using plastic pipe to run the wires.
      
We're running a new electrical wire & wondering if it would be ok to place it where indicated in the pic... or should we cut out more wall to the left & get it away from the water lines?
      
I live in the bottom unit of a 6 unit bldg. We have the filters and everything in a room off of our unit. We also have a breaker on our panel for the pump. I haven't tested it yet by shutting off the breaker (mainly due to long hours at work lately and nobody is awake when I am home), but is it possible/probable that the pump for the whole bldg is running off of our meter? There are 6 total units and 6 total meters outside, so there is no obvious meter for the pump circuit (plus the breaker is on OUR panel).
      
I am wiring a three phase motor through a two pole vacuum switch. two lines go through the switch but one line is always hot to the motor. is this proper or is this a safety issue?
      
Getting ready to replace my well jet pump with a 240 volt model (currently I use a 120 volt pump. Currently I have a 20 amp, 120 volt circuit that runs from the house to the pump house about 60 feet. I use that circuit for the pump, a light and a receptacle. I want to replace that circuit with a 20 amp MWBC using 12/3 UF cable from the sub panel in my detached barn to the pump house (about 20 feet).



Question: Can I use 1/2" seal-tite to run from the sub panel to a a junction box prior to going underground with the 12/3 UF? The seal-tight run would be about 30". (I have a bunch of seal-tite, connectors and #12 THWN that I bought cheap at a storage unit auction.) The seal-tite would be run in the stud bay and along side the ceiling joist to get from one side of the barn to the other.



Question: Can I use an unfused air conditioning disconnect at the pump house to disconnect the 2 ungrounded conductors of the MWBC.



I can find nothing in the NEC that would bar either of these items, but I am a code novice.