Closet Light

With a hard wired LED closet light fixture, can it be wired like an undercabinet fixture? clamp the wire to the light and push the excess wire into the ceiling?

 

Or can i install an outlet on the ceiling and use the plug in style lights?

 

Im going to install a switch outside of the closet so there will be 1 wire going to the light.



What is the best way to do this?
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Hey guys and gals,



got a very odd dilemma, in my dining room there is a chandelier lamp that is controlled through a dimmer switch(even though it is not a dimmer). There is also a closet with a light switch as well.



The odd circumstance i am having is when the closet light is on(via its own switch), and you turn on the dinning room light, the closet light goes out. Then if you turn the dining room light off,the closet light turns back on.



The closest light switch has zero effect on the dining room light, the dining room light seems to have control over the closet light and dining room light.



Any ideas on a fix. I was thing just replacing the dimmer(once again does not actually dim) with a single pole interrupter. I just dont want to burn my house down
      
I want to put an outlet in a closet for a plug in transformer for the alarm control box in the closet. Is the outlet in the closet permitted by code?
      
I am working on fixing an issue with the wiring in one of the bedrooms in my older mountain home. Though I was not present for the cause of the problem, here is what was told to me by the tennant.  he claimed that he went to turn on the light in the closet, (a 3 lamp track bar light, wired to a switch) he heard a loud pop from the light in the closet and lost power to to the room. The room has 6 recessed ceiling lights on 2 separate switches, presently only half of the lights work.There are no breakers tripped, no obvious shorts at outlets. I have opened the drywall following the wires around hoping to find a short but I have found nothing. I decided to try something, and I bridged the working switch to a dead outlet and everything turned on. I am waiting til the daytime to follow the wires outside to the breaker box, but so far no breaks or anything.. curious if anyone has any pointers.. could the pop he heard from the track lighting have killed a breaker? its about the only thing left.
      
Hello. I'm a new home owner and DIY-er. I have 3 fluorescent lights  in my basement. I just replaced the fixtures' older ballasts with new  T8 ballasts in the first two lights and they work fine. I am having  trouble with the third light's wiring to the ceiling. I cut and removed  the old ballast without paying much attention because I was able to wire  the first two lights without any problem. I connected the new ballast  to the bulb sockets in the fixture, just like I did with the first two  lights. When I went to connect the ballast's black and white power lines  to the ceiling lines, I was thrown off by a red wire, which I guess is  connected to the light switch.  In addition, this light is connected to  the one of the other fluorescent lights and both are controlled by the  switch. I have attached  pictures of how I have it wired.



The way I have it wired now,  the other light turns on and works fine when the switch is flipped.  However, this light has the bulb flicker and then not turn on. If anyone  can tell what I'm doing wrong from looking at the pictures, I'd  appreciate any help! Thanks!
      
We are just beginning to start with our kitchen remodel. Today, I mapped out all the circuits and this is what I found.



Circuit # 7 - 20 amp circuit to 1 back splash outlet then to 3 kitchen wall outlets, then to a closet outlet and closet ceiling light and then to a side  porch light!



Circuit # 8 - 20 amp to Dishwasher and Disposal



Circuit # 9 - 20 amp circuit to microwave and kitchen ceiling lights. 2 patio recessed lights and dining room ceiling light.



Circuit # 12 - 20 amp circuit to another back splash outlet then to 2 dining room wall outlets.



Circuit # 14 - 20 amp to Refrigerator only



Circuit # 18 - 15 amp to GFCI outlet in garage then that feeds 3 outlets for 3 bathroom outlets and 1 outside patio outlet.



I going to have to add 1 more back splash outlet due to increase in counter space. I'll put the microwave on a dedicated circuit. So I need 2 additional breakers but I only have 1 blank spot in the breaker panel. I guess I can add one of those slim tandem breakers.



So my question, is it ok to have additional wall outlets on the same circuit as a back splash outlet?  If it's ok I'll lighten up circuit # 7 by putting some of those wall outlets on the additional back splash outlet.

Oh, I have 2 20 amp circuits I did not get identified yet! I'll get to those tomorrow.



thanks!
      
I am going to install some can lights throughout the house soon.  I have one light in the center of each room that is already wired up.  I will be patching the existing light boxes up to run the new can lights, utilizing the wiring that is already present. 



When hooking the extra lights up should I use 12/2 or 14/2 wire for running them in parallel?  There will probably be no more than 3 or 4 can lights per room ran with CFLs.  The current lights that are in each room take up to 3 bulbs per fixture.
      
I'm installing a new light in a closet with an in-line switch. Because of the build of my house, a mid-run receptacle is the only power source available without ripping open a bunch of wall and ceiling. I've got everything installed and tied into the receptacle with appropriate pig tails, but whenever I turn the power back on, the breaker for that circuit instantly flips. I've double-checked all the connections and wires, and they are connected to the appropriate terminals. Tied the pig tails into the terminals on the top socket of the receptacle.



Could this be the result of a faulty switch? The breaker trips whether the switch is in the off or on position, and there are no bulbs in the light fixture. I'm stumped. The receptacle in question is rarely used, and I've powered off everything else in the room to be on the safe side, but the breaker trips.
      
Greetings!

I'm hoping for some help, I bought a house recently where the laundry room light switch does not work. I found this in the ceiling box:



Two black wires capped off

One white wire capped off

Three white wires going to the fixture

Two black wires going to the fixture



I replaces the switch to rule that out and it still doesn't work.



There is one black and one white wire going to the switch.



Any ideas on how to wire it properly?



Thanks!
      
I raised a shed and disconnected the wiring from the main building to the shed. Now it's a month later and it's time to hook the power back up. From the main building I have power into the shed with a white, black, red and copper wire. Originally the power went into the outside light fixture and then off of that it went to another light and two outlets. The original confiruation allowed of us to turn the shed's outside light on and off, from a switch inside the main building. With the power off to the light, we still had power to the outlets and internal light. The outside light fixture has black and white wires. The wire to the internal light and the outlets has a black, white, and copper wire. So how do I wire this so that the main building switch can control the outside light on the shed, while still having power to the internal light and outlets, regardless of the switch being on or off? (I wired the internal blacks and whites all together, which just ended up with the outside light always being on.)
      
I am currently remodeling a bedroom in my home for a new baby.  I have gutted the room and am replacing all the electrical and adding new recessed lighting.  The room will also have a ceiling fan, along with the recessed lighting.  I am looking for a single gang light switch that will operate the ceiling fan independently of the recessed lighting, with a dimmer for the recessed lighting.  I don't have room for a double gang box where the switch is currently placed, as there is a closet in the way.  Is there such a thing as a switch that will operate the ceiling fan and it's lighting on a normal on/off switch, with a dimmer that can independently control the recessed lighting?  I have checked with the local big box stores and everyone has told me I will have to run two switches.  Is this the case?  Any info would be greatly appreciated.  Thanks in advance.