Hello I need seriouse help! In my situation I have a three switch, one for the light, one for the vent fan, and one for the heater. This is in a bathroom rent house. My problem is that when I turn the switch on for the light, the light and fan turn on, when I switch the heater on, that switch does nothing, the same when I switch the fan on. The wall plate is labeled: light, fan, heater. So what I attempted to do is put a switch outlet combo in. I have two black wires, two white wires and a ground. So I put the black wires on brass and the white wires on black,( they are black screws instead of silver, not sure if I got the right kind of switch). So when I did that, when I turn the switch on, the fan turns on, but no light, also when the switch is on the outlet is hot.( which fine that is how I want it). But what did I do wrong, why does fan work but not the light. I my biggest fear is that I might have made a fire hazard. Please help and tell me if what have done is safe, and maybe help me figure out how to turn the fan and light on with the same switch..  Thank you for all your input, have trouble falling asleep, keep thinking the house might burn down.. Sorry for the long post
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Hello all, and thank you in advance for any help you can provide! Here is the deal I wanted to put a bathroom exhaust fan in and was told I could come off the existing switch to cut the wire, install a junction box, tie the wires all back in adding the wires for the fan. Trouble is the bathroom light stays on with the switch off. Turn the switch on light dims and the fan now runs, switch off fan shuts off light goes bright used black to black white to white where oh where did I go wrong!?
      
Hi, I have a problem where if I turn off my light switch on one side of the  room, it turns off anything plugged into the electrical outlet on the  other side of the room. For some reason, they originally wired that  outlet on the same circuit as the light switch. I would like to wire the  outlet so that it does not switch off whenever you switch off the light  on the opposite wall.



How do I go about doing that? Thanks.



(p.s. There are just the basic three wires in the electrical outlet; black/white/bare copper ground).
      
This should be simple but . . .



I am replacing a couple old 3 pole switches with 2 new decorator switches. First switch I rewired exactly like the old one black on black pole, a second black on brass pole on the same side, and red on the pole on the other side.



I rewired the second switch exactly like the old one was too.  White on black pole (I know ) red on the brass pole on the same side, and black on seperate pole on other side.



light will turn on and off from first switch but only off from second and will not turn on from first switch if second is turned off.



so I rewired second switch with balck on black pole, white on top brass pole, and red on seperate pole.  Nothing changed.



Do I need to test which wires are actually connecte to each other in the wall or what?



thanks for your electrical wisdom
      
Hello!



In a house I recently bought I have a strange situation.



There is a three way switch on one side of the wall with two sets of wires coming in:



Red, Black, White

Black, White



and then one stray Black that goes to the duplex receptacle on the other side of the wall (on the OUTSIDE of the wall!  Clearly an afterthought.)



Into the receptacle goes this strange black single wire from the light switch and the usual black and white wires + ground wire.



I went to change the ugly receptacle to a decora and now it doesn't work, though I'm not 100% sure it worked before.



I've wired the new receptacle as I remember it being wired before, any idea what is wrong? 



I've attached a diagram!



Thanks in advance for any input.
      
Hi, I recently moved into a 1954 house with a  20amp electrical system, not the old fuse type, but there are no ground wires.



I removed an old light and replaced it with a light fan combo. As I removed the old light (after turning off the breaker) I noticed from the ceiling that there were 2 white wires tied together with a wire nut and 2 black wires, one attached to the white wire in the light and the other attached to the black one from the light. Feeling this was wrong and should be black to black, white to white, (even knowing full well the light was working fine before I disconnected it) I wired the fan the way I've always wired fan lights,  white to white, blue and black to black.  (again, knowing full well the light was working the other way). Turned breaker on then powered on switch. POP at the switch, breaker switched off. I reworked it back to the way it was before with whites tied off, black to white, black and blue to black, turned it back on and  viola, things worked fine. (I know, duh... Right???)

2 questions from this experience...

1. Why would the 2 whites be tied off with only black wires used?

And 2. It seems that one of the light switches in the same circuit as the blown one is now working soft. In other words, it used to make the normal click noise when turned on/off but now it just moves softly up and down without the click. Could I have damaged something when I mis-wired?
      
I am replacing the fan in one of our guest bedrooms and thought it would also be a good time to replace the switch.  Currently there is one switch to turn the fan and light on/off. 



I'd like to put the fan and light on two separate switches.  It appears that 12/3 or 14/3 is already in place (white, black and red/pink wires in switch enclosure w/ bare copper for ground).  I'd also like to make the light dimmable and the fan speed adjustable from these switches.  Could anyone recommend a good switch(es) to accomplish this?
      
Older house with the metal enclosed wiring has stumped me.  I am attempting to add a second switch for a fan off existing light switch in bathroom.  Existing wiring:  W,B,R from panel, W,B to light.  2 white wire are tied together, two black wires to one contact and red to other contact on switch.  Disconnected all wires and confirmed the black is live from panel.  It seems to me the light is seeing power the entire time since the blacks are connected? I'm confused, please help. how do I add another switch onto this circuit?  Thanks!
      
Am doing a bathroom reno and installed a new fan. Original switch was a simple on off single pole. I want to install a DewPoint condensation fan switch that will turn on automatically at a certain moisture level.

The new switch as 4 wires. green ground, red fan, black power, and white neutral. I know the ground, but how do I hook up the neutral and fan to the existing fan set up?

There is a double pole light switch in the same box that has a couple wires to it, and there is a mass of whites that I am not sure where they go



Can I hook up the neutral somewhere else, or put it with the fan like a single pole? What do I do with this?



In the attached picture the switch on the right is the 2 pole light switch and on the left is the fan switch that I hope to replace.



Your Advice is appreciated
      
Greetings!

I'm hoping for some help, I bought a house recently where the laundry room light switch does not work. I found this in the ceiling box:



Two black wires capped off

One white wire capped off

Three white wires going to the fixture

Two black wires going to the fixture



I replaces the switch to rule that out and it still doesn't work.



There is one black and one white wire going to the switch.



Any ideas on how to wire it properly?



Thanks!
      
Hey guys and gals,



got a very odd dilemma, in my dining room there is a chandelier lamp that is controlled through a dimmer switch(even though it is not a dimmer). There is also a closet with a light switch as well.



The odd circumstance i am having is when the closet light is on(via its own switch), and you turn on the dinning room light, the closet light goes out. Then if you turn the dining room light off,the closet light turns back on.



The closest light switch has zero effect on the dining room light, the dining room light seems to have control over the closet light and dining room light.



Any ideas on a fix. I was thing just replacing the dimmer(once again does not actually dim) with a single pole interrupter. I just dont want to burn my house down