Two Switches Wiring Question

Hi All,



Need to replace an old faulty two switch fixture in the bathroom (light and exhaust fan). Right now, each switch on the single fixture separately operates either the light or the fan, regardless of the position of the other switch. Want to keep things that way. 



Here is a picture of the old fixture's wiring: http://dl.dropbox.com/u/1179096/photo1.jpg



To replace this fixture, I bought to the Leviton 5634 (design diagram he  http://communities.leviton.com/servl...224%205634.pdf)



Unfortunately, what is confusing me is the the different designs between the two fixtures and the fact that the original unit seems to have some kind of patch or cross over type wire connecting the top and the bottom switches (see photo link above).



Any help/advice on how to wire this new fixture based on the picture of the current wiring configuration would be greatly appreciated. Thank you!!!
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

When repairing a light switch I came across this wiring in a supposed 3-way setting in my kitchen.  Two Single Pole Double Throw switches controlling a single light fixture. 



Check out the quick and dirty wiring diagram showing the way these are connected.  I believe there should be a 14/3 between the two switches right?



All I see is 14/2 coming in and a 14/2 going across to the other switch, and then a 14/2 going to the light. And why are the neutrals cut and wire capped?  This doesn't make sense to me, but the light does work from both switches.



Any insight will be greatly appreciated.



Cheers!
      
wanted to get feeback on my crude wiring diagram i put together for my small bathroom remodel. does it appear to be sound or am i way off base??



details:



* 20A dedicated circuit

* 12/2 wiring

* outlet's will be GFCI

* double gang box will contain:

* timer unit for exhaust fan

* double switch for heat lamp and lights

* Ground wiring is not shown but each fixture/outlet/switch will be connected to ground wire

* by calculations, the 34cu box is fine for the number of conductors/size of wiring. per box specs could handle 15/12g wires.

* the scanner cut off the bottom part of the picture, the 2 lights on the right are fed from the same switch, neutral's connected together.



F = Exhaust Fan

L = Light

HL = Heat Lamp

T = Timer switch

S = Switch

H = Hot

N = Neutral

Wire Nuts are in the box connecting the pigtails



Thank you for your input.
      
Hello,



I am replacing a bath light and I am a bit confused by the wiring. I can reattach the wires with the new fixture exactly like the old fixuture was attached but the old fixture did not have a ground connection.



Here is how the wires a



Two whites connected to each other but not to the fixture.

One white and one bare copper wire (I thought it was the ground) connected together and to the white wire of the ligh fixture

one black wire connected to the black wire of the light fixture



How to I connect the the fixture green wire in this configuration?



Thanks
      
Hello there,



I just installed a new fixture in my dining room. It has 5 MR16 halogen bulbs. When i turn on the light switch, the lights are gradually turning on to full brightness. The process takes a between 5 to 10 seconds.



I removed one of the bulb and noticed it took a bit less time and continued until I had only 3 bulbs and then the lights are turning on instantly.



So I think its obvious that the fixture is drawing too much power from the circuit. My question is, why? What tests can I dk to find the cause? Is it a faulty switch or faulty wiring?



Thank you!
      
I have an outdoor light fixture that I am trying to replace.  The house was built ten years ago.



When I removed the original lamp, I noticed one of the two leads was wired to the ground, and one was wired to the black wire, which is hot per my current sensor.  There are three wires in the box - black, ground (bare copper), and white or neutral, all from a single romex cable.  Unfortunately, I do not recall where the white was when I removed the original. 



I wired the new lamp per the instructions, something I have done many times before - black to black, white to white, and bare copper ground to ground.  Nothing.  The lamp and bulbs are brand new, and I have tried four separate bulbs.  I checked the black and neutral with my current sensor and with the switch on and the lamp installed this way, both show as hot. With the lamp not installed, the switch on, and the wires disconnected only the black shows as hot.  The switch is single pole, and appears to be wired correctly with a black to each screw on one side and a copper ground on the other.



Assuming the new fixture was bad, I reinstalled the old fixture correctly -  black to black, white to white, and bare copper ground to ground.  Still nothing. No light, and I confirmed the bulb is good by putting it in another lamp.   The only way to get it to light is to connect the neutral in the lamp to the bare copper ground.



I capped the wires, turned the circuit back on, and identified all the outlets, switches and fixtures on the same circuit.  I opened every one of them up (four lights and eight outlets) and found three (one switch and two fixtures in another room) where multiple commons connect.  All were properly connected.  My outlet tester shows all outlets as "correct".  I found no instances of grounds connected to commons or vice-versa.



Any ideas?  Is it proper to wire this thing the way I found it?



Thanks for any and all advice!
      
I bought a LED fixture that fits in a 4inch can

http://indoors.pricegrabber.com/show...s/m/928501559/



The thing iswhen I pushed the fixture in I niked the black wire from the can's socket. What should I do replace the socket or should I just take the can's socket out and also the LED socket out and use marettes?   The thing is I don't have much cable from the box the romex is about 6 inches long and was cut to lenght!!!
      
Hi everyone,



I'm pretty new to the whole homeowning/do it yourself lifestyle, and have a question about the light fixture in my kitchen.  Recently 2 twisted cfl bulbs went out, probably within 1-2 days of each other, and I am having a hard time figuring out how to replace the bulb.  I believe the lights in my kitchen are considered recessed lighting.



So when the first light went out, I hastily grabbed my step ladder and tried to twist the bulb out.  I should have looked more closely at the fixture because when I started to twist, the bulb popped in my hand.  No big deal, just a bunch of debris all over the place.  I looked at the fixture and it said I should pull straight down to remove.  Doh!  The second light went out a day or two later and this time I pulled straight down on the bulb to remove.  To my surprise the bulb came out, but at the ends of the bulb were 2 bare wires.  I had never seen this bulb in stores before.



Anyways here are some pictures I took of my fixture.  Can anyone tell me how I am to replace my busted bulbs?  Thanks!












      
Greetings!

I'm hoping for some help, I bought a house recently where the laundry room light switch does not work. I found this in the ceiling box:



Two black wires capped off

One white wire capped off

Three white wires going to the fixture

Two black wires going to the fixture



I replaces the switch to rule that out and it still doesn't work.



There is one black and one white wire going to the switch.



Any ideas on how to wire it properly?



Thanks!
      
I am installing a ceiling fan for my mom and the wiring has me a little confused. I posted pictures below of the ceiling fan wiring and the light fixture wiring. Just need to know how to connect the two together without burning down the place. Thanks in advance






      
I'm using some lampholder fixtures for lighting in my garage and I'm wondering what to do with grounds?  There is nowhere to attach the ground wire to the box or fixture, so what do I do with it?  Neither the box or fixture is metal.  And what do I do with all the grounds in the switch box?