Best Place To Buy White Switches/receptacles?

updating an older home (1927) and would like to replace all the receptacles/switches/plates with newer Lutron style white switches, where is the best place to order these or pick them up?  Not sure if its worth shopping online or if the big box convenience negates cost difference?

Thanks!
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I admit, I'm jealous of the European style light switches, with the little white buttons instead of the standard switches they have here in Canada. I don't know much about the design of the European wall switches, other than they are designed for 250v 10a systems. And that I can buy them on eBay! So I am wondering if anyone can tell me whether it might be possible for me to install the European 250v light switches on a North American 120v system?
      
I am replacing the fan in one of our guest bedrooms and thought it would also be a good time to replace the switch.  Currently there is one switch to turn the fan and light on/off. 



I'd like to put the fan and light on two separate switches.  It appears that 12/3 or 14/3 is already in place (white, black and red/pink wires in switch enclosure w/ bare copper for ground).  I'd also like to make the light dimmable and the fan speed adjustable from these switches.  Could anyone recommend a good switch(es) to accomplish this?
      
I have two 3-way switches in my master bath that have never worked properly. The house is very old and has been worked on over the years by many different people with greatly varying levels of skill. I was finally fed up with these switches and tried to fix them. I tried to follow instructions I found online, so with the power off I disconnected all the wires from both switches, then turned the power back on and used my volt-meter to discover which wire was hot. It turned out to the a red wire at switch #1. The other two wires are white and black (and yes, there also is a ground). I connected this hot wire to the darkest screw, connected the white and black to the other two screws and tried to test for continuity at the other switch. I couldn't get a reading on any of the wires at the other end. I tried turning the power back on and testing to see which wire was now hot at the second switch. It was the white wire, so I attached that to the darkest terminal, and attached the red and black to the other two terminals. The switches don't work any better than they did before I started - that is, both switches have to be turned on for the light to come on. What is my problem here? Thank you!
      
How long would you expect to take to replace 5 receptacles in one room, if you were by yourself (no helper)? The task is to simply replace the receptacles and switches with new ones, but upon inspection, you find that though the system is grounded through an unknown property (either conduit or AC), thee is no EGC wire for attachment to the metal box; you'd therefore (I assume) want to run a 6" piece of wire for the ECG from receptacle to box.



I assume the extra bare wire here as I don't believe the receptacle yoke should be relied upon to provide a solid bond.
      
Hello -



I'm attempting to install a new bathroom vent fan / light combo.  I pulled out the old one from the ceiling and am ready to install the new one.  I'm not sure how to wire up the new one.



The wire coming from the 2 Switches/Wall has the following 4 wires:  Black, White, Red, Bare Copper Ground



The wires coming from the Light/Fan Unit a

Light:  Black, White, Red

Fan:  Black, White

Fan/Light Housing:  Green Ground Wire



Any help would be appreciated.



Thanks!
      
I am having a garage/shop built on my back lot.  The PoCo will place a meter pan with a disconnect switch (not an OCPD) on a utility pole that is already in place and about 40 feet from the garage.

What will I need for temporary construction power?  I know I need GFI receptacles and OCPD but what about the ground?  Will I have to drive a rod?
      
Finishing basement and have a few questions...



1. Have already bought recessed cans. Commercial Electric brand. I have now read a few places that these are junk. Why exactly and should I return them? Need to know know before I paint them black.



2. I plan on installing 12 lights on new 15A circuit using 2 switches one for left side of basement one for right (6 x 6). This is OK yes? Both switches will be in same box. And will be only thing on this new circuit.



3. Assuming I am running hot lead from main panel to switch box...there is no fancy wiring that needs to be done correct? 14/2 black to black, white to white except at switch correct?
      
I have a single receptacle with 12/2 on a GFI (20 amp). I ran a 3 wire (14 gauge) to my other two receptacles and put a tandem breaker in the panel. Should I wire the receptacles as single receptacles on individual GFI's or split receptacles? They are more than a meter away from the sink. Also I have read the two 15 amp circuits should be on separate phases? How do I insure this?  Thanks gentlemen!
      
Im replacing what I thought was 2 single pole light switches but there is 3 black wires and one red. I hooked them up to the new switches but both switches worked the one light can anyone tell me how to connect the wiring?
      
I was changing out old switches in an old apartment when I came across this enigma. Switches in the kitchen and hall both operate the hall light. The switch in the kitchen was a regular 3way switch job with a red, a black and a white wire. The switch in the hall had four wires, 2 black and 2 white. I replaced this with a 4way which my husband said was incorrect. In the mean time until we find the correct type of switch (which I'm open to suggestions) we put the old ones back on but must have messed something up because now the kitchen switch only works when the hall one is positioned "down".  I have multiple questions. What is the red wire hooked to? None of the wires in the 4-wire box read 110v so which one is the power coming in from? I'll stop here for now.  Thanks.