Limitation To Number Of Receptacles?
Is there any limitation as to how many receptacles can be protected by one GFCI receptacle? For example, can I start the circuit with a GFCI and have another 8 receptacles downstream from it?
Similar Tutorials
How to Lay Sod - The Right Way!
- Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
- This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
- If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ... Similar Topics From Forums
Hi all, this is my first post, so...my kitchen was just renovated and the electrical outlets are on the walls and I wanted them in plugmold under the cabinet. Why didn't it happen? Long story, but I'm doing it myself now. The electrical receptacles are on 2 separate circuits with a gfci receptacle on each and neither circuit has a receptacle outside the kitchen where I can put the gfci's, so I'm putting gfci breakers in the panel instead. I've run into a different problem on each circuit that'd like some advice on.
Circuit 1: this is a 20 amp circuit. I have to plug this circuit's neutral wire into the gfci breaker, but I couldn't see which neutral wire matched the hot wire (buried in mess of wires) and I don't have a continuity tester so I just pulled one neutral at a time (tedious) until the circuit failed, but it never failed. So I did this again for every neutral...same result. This circuit shares a few boxes with other circuits so I'm wondering if the neutrals on different circuits are tied together somewhere, and if so I'm pretty sure, but not completely, that that's not going to work with the gfci breaker. So I didn't install that gfci breaker since I'm not confident it would actually gfci (yep i verbified gfci). What do you think? Circuit 2: this is a 20 amp circuit. This circuit currently has the refrigerator, gas stove and range hood, and then a gfci in front of 3 electrical receptacles, which already sounds bad since I thought the kitchen receptacles required 2 dedicated circuits. I replaced that breaker with no problem, but it tripped after a few minutes and continued to trip every few minutes. I haven't changed anything else on that circuit yet and it's never tripped before, but now it is, so I put the old breaker back for now. The current gfci receptacle is only protecting the 3 outlets since the appliances are ahead of it. I know you wouldn't normally want the appliances gfci protected, so do you think the refrigerator motor may be a problem? Do I need the appliances on a separate circuit? What would you suggest I do? Thanks, and if you're wondering "why all the effort?", it's partly because I'm meddlesome, partly because I'm bored, and partly because the backsplash tile is to be on showcase, not the electrical receptacles.
Hello.
I recently purchased a home that has a a new grounded breaker panel but none of the outlets themselves are grounded save the hvac system in the basement. I had an electrician come and he said the fastest way to get it done is to switch the appropriate breakers to GFCI breakers in my service box and then I can change the outlets and then just put the stickers that say ungrounded etc on the new 3 prong receptacles. he called the inspector to double check and the inspector told him that he can't do it this way but he needs to find the first outlet in the loop from each breaker line and change that receptacle to a gfci and then we can change each receptacle to 3 prong in that loop. Wouldn't just changing the breaker do the same thing? also if I did just install a Gfci receptacle on the first outlet in the loop, if it breaks wouldn't the rest of the outlets behind that gfci not function until I replaced the Gfci outlet where as a breaker would just pop and I can simply go turn it back on? Just wanted to get some opinion from the experts as I'm willing to spend more on doing gfci breakers and am confused as to why the inspector suggested the way he did Thanks for any help!
I have a single receptacle with 12/2 on a GFI (20 amp). I ran a 3 wire (14 gauge) to my other two receptacles and put a tandem breaker in the panel. Should I wire the receptacles as single receptacles on individual GFI's or split receptacles? They are more than a meter away from the sink. Also I have read the two 15 amp circuits should be on separate phases? How do I insure this? Thanks gentlemen!
Hi all,
I have two outdoor receptacles that are wired into a junction box in the crawlspace under my house. They are actually ran into a spare bedroom's circuit...therefore not gfi protected. There is a switch above the access (indoors) to the crawlspace that powers these outlets and also light that runs off of the junction point also. Would I be able to replace the switch with a dead front gfci switch to get these outlets protected. Would doing this be safe and up to code? Would I be better off undoing all of the previous owner's work and putting these on a dedicated gfci circuit? House was built in '87 and I am in the US.
Can an outside receptacle be protected by a GFCI on the inside of my garage or must the recep. outside be a GFCI aslo?
If you have a 20 amp circuit going to your bathroom vanity, can you have two 20 amp receptacles on it, one a GFI receptacle and the other a standard 20 amp receptacle wired to the load terminals of the GFI receptacle ?
Or does the code require each receptacle to be a GFI on its own circuit ? Arky
New appliances coming in. No change in service, so I believe that existing wiring can be considered grandfathered. Please correct me if wrong. BTW: we're under 2005 code in my locality, but I go with 2008.
Currently, the kitchen is wired all 15-amp except for non-counter-top receptacles. (I know, opposite, and wrong, but that's the way it is) Can dishwasher and disposal be on same 15 amp circuit? (This will be a new circuit, so perhaps I need to run 20-amp?) Current range wiring is 3-wire on a 40 amp breaker (3-pole). Can I still utilize a 3-prong receptacle here? Does the kitchen wiring have to be upgraded to provide for 2 SABC (currently, only 1), and 20 amp?
How long would you expect to take to replace 5 receptacles in one room, if you were by yourself (no helper)? The task is to simply replace the receptacles and switches with new ones, but upon inspection, you find that though the system is grounded through an unknown property (either conduit or AC), thee is no EGC wire for attachment to the metal box; you'd therefore (I assume) want to run a 6" piece of wire for the ECG from receptacle to box.
I assume the extra bare wire here as I don't believe the receptacle yoke should be relied upon to provide a solid bond.
I currently have a shower light and fan wired downstream from a GFCI receptacle. I am pretty sure they are wired into the load side of the GFCI. I will make sure again after work today. My problem right now is the light and fan does not trip when the TEST button is pushed. Only the receptacle will trip.
What did I do wrong?
That means it applies to the entire country
Permits & Inspections are usually required for ALL electric work It may not be legal for you to do your own work, Check with your local Building Dept This thread will be added onto as a form of "Cliff Notes" for the NEC If there is something that needs to be corrected, or if you wish to add to this thread; please let us know The NEC is available online, you may have to sign up for an account to view it: http://nfpaweb3.gvpi.net/rrserver/br...NFPASTD/7008SB (may not be working) Draft Version: http://www.nfpa.org/assets/files/PDF...08ROPDraft.pdf Also a link to State specific NEC/Building codes: http://bulk.resource.org/codes.gov/ New Code book comes out every 3 years, it is not always fully accepted by States & sometimes not until 1-2 years later Local codes can vary from the NEC 210.23 An individual branch circuit shall be permitted to supply any load for which it is rated (some think you can only load to 80%) 210.50 Required Branch circuits 14g wire is rated for 15a, 12g wire is rated for 20a 15a outlets ONLY on a 15a circuit 15a/20a are allowed on a 20a circuit A single 15a receptacle is not allowed on a 20a circuit AFCI protection is required almost every where under NEC 2008 Exceptions are GFCI required: bathrooms, kitchens, laundry (GFCI if sink within 6' of receptacle), garage & outside circuits Bathroom requires a dedicated 20a GFCI protected circuit that can serve outlets in multiple bathrooms OR Outlets & Lights in One bathroom Kitchen requires 2 dedicated 20a GFCI protected circuits for counter (no lights) Laundry area requires a dedicated 20a GFCI protected circuit . . |