Wire In Conduit

Just curious which is the prefered way to get the electrical cable through the conduit, and why? 



I see some pull a rope through as they glue the conduit and pull the wire when done.



Others feed the cable through each individual piece of conduit as they go along. 



Thanks in advance for your answers.
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I am running power about 180 feet to power a 60A subpanel in an outbuilding. I am expecting to use 2-2-2-4 AL. The run is underground for about 150', and the balance through crawlspace and basement to the panel. My question is: can I use a sheathed cable such as SEU in the conduit so I can simply continue (unconduited) under the house, or do I have to run URD in the conduit to a juction box and change to a sheathed cable to run under the building?  Or can i run URD in the conduit under the house to the panel (this would be less preferred). Thanks
      
Need a little advice... Here's the scenario:



-200 amp meter/main.

-2 small side by side residences with 80 amp load each.

-Each residence has a 200 amp panel with main disconnect.

-1 3" conduit from meter to underground pull box between both buildings

-A 2" conduit from the pull box to each building.

-All conductors to be 3/0



Is there any reason why a 3/0 feeder with ground could not be pulled to the

pull box and then split to run to each building instead of running 2 separate 100 amp feeders? Any other things to consider?
      
I have an older home and i wanted to add a new 15 amp breaker for a circuit for the outlets for my upstairs. I noticed that the existing old black romex runs from the circuit breaker in electrical conduit in my walls. There is no way i can get more romex through that conduit. Can i add the romex outside the electrical conduit? i am not really sure why they ran through the conduit to begin with.
      
I want to run Romex from a j-box, that is in the ceiling of my basement, to the main panel.  I know that I can run Romex from the box along the face of the joist (not the bottom), but what are my options once the Romex gets to the wall?  The joist I am using, conveniently enough, meets the wall ideally for where the panel is.  However, I've read that I need to run the Romex through EMT, or some form of conduit.



If you look at the picture I've attached, the panel is mounted on a piece of plywood that extends out underneath the joist.  Can I just staple the Romex to the plywood and then run it into the panel without using any conduit?  The cast iron pipe makes using any conduit quite a problem.



The cable you see is MC Lite, but I want to replace it with Romex.  There are going to be up to 9 more lines coming into the panel this very way.
      
Is it ok (up to code) to connect 2" rigid conduit to the breaker box using this type of hub  menards.com/main/electrical/rough-electrical/metal-conduit-fittings/2-water-tight-hub-insulated/p-1442092-c-9538.htm  ??



The conduit will exit the panel at the top, go up about 6", then to an LR, then out to the meter about 6' away.  The 6' run will be supported.



Thanks.
      
I am selling my house and the Home Inspector said that the basement surfaced mounted receptacles needed to be in conduit because the wires were exposed.  He didnt say anything about the exposed wiring that was stapled to the bottom of the joists had to be in conduit.  Can I just leave the exposed wires on the joist exposed or do I have to but them in conduit too?  Could I also just drill the joists out and run the wire inside them?  Is there a code about this?  Did the Home Inspector forget this?   What would happen if I only fixed the receptacles with conduit and nothing else?  Thanks In Advance!
      
I have 2" grey pvc conduit running from my basement underneath a patio and terminating vertically from the ground a few feet past the edge of the patio (in the dirt).  I want to install an outlet on the stone wall at the edge of this patio.  I do not know how to properly return the wire from that open 2" vertical conduit back to the wall a few feet away.  I assume I need a junction box on the existing conduit, but can't find one with a 2" inlet.  I would like to keep the connections buried if possible, return with a smaller conduit to the wall and up to a mounted outlet box (weatherproof).  Any suggestions about how to manage the conduit connections from the vertical pipe?



Tom
      
I have a lamp post outside that I am going to replace this spring with a new one... right now they just have 14-2 romex ran underground to it... not in a conduit or anything... should I replace this with UF cable? or is NM cable still the way to do something simple like this? Also should I use conduit?
      
Our pool was installed 10 years ago and we need to change the 3 underwater lights because they are leaking. The cable for each light box goes through a conduit and up to a "deck Box" or junction box per code so water from pool can't run up to the box. In order to change the lights we need to locate the box and pull the wires out, then feed the wires through for the new light. The problem is that one of the boxes seems to be missing. That light sits under a stone waterfall and there is a planting area behind the waterfall. Ive searched under all the bushes and even done a bit of digging but cant find the box. I'm wondering if there is some smarter way to locate it.



I tried a metal detector but there were too many false alarms from every metal scrap the work men left behind. I was wondering if there is something that could be fed through the conduit to junction box that would send a signal allowing it to be located. I know the cesspool guys use something like that and thought maybe an electrician might have a similar tool.



The new lights are completely different than the old ones so we can't just change out one. if we can;t change this light we can;t change any of them and the whole project goes down the drain. Any suggestion would be greatly appreciated.
      
Q1-

isn't rigid conduit supposed to bottom out in hub on new service panel? I thought so, installed mine and the threads look fine but only threaded in about 8 turns then stopped. Same on the other end.

Q2-

i'm trying to figure out how to brace my service entrance rigid conduit in my garage wall to my service panel. the conduit is 1 1/2 inch and the studs are 3 1/2 (2x4) so there's no room for cross bracing behind the rmc.i was gonna brace then strap but no room(stucco exterior) any ideas??

Pics are attached any help is greatly appreciated-

Steve