Grounding Steel Drain Pipe
In a 1950s home the electrical is being redone. Wallboard was removed in the kitchen and there is a kitchen sink drain/vent line (seems to be 1" to 1-1/2" pipe) in the wall which is made of steel. It runs down into the concrete slab and up through the roof. There is an old electrical outlet (which will be removed and replaced) next to it which has a 14/2 cable and a separate small ground conductor running to it. With a meter I measure 50V between the steel pipe and the steel housing of the receptacle. Once the old receptacle is removed and a new one is installed, where and how will the drain pipe be grounded? I am sure there are more steel drain pipes used in this house but not all of them are open and exposed. Will it be sufficient to ground this one steel drain/vent line? If yes how and with what conductor size?
Similar Tutorials
How to Lay Sod - The Right Way!
- Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
- This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet � What do I do? (How to replace the wax seal for a toilet.)
- If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ... Similar Topics From Forums
I am having my inground pool renovated. The pool is made from aluminum panels. They will be replacing about 5 panels with steel and the contractor said they need to be grounded. Now I have checked the rest of the panels and there is no evidence of any grounding that I can see. The only thing I have found is at the end of the pool they will be repairing there was some wire connected to the top railing and buried into the dirt.
I have worked with electrical contractors when I was younger and do electrical work at the power plant I work at. How would I ground these walls and what materials do I need.
I removed the light above my vanity and found that the the previous installer did not install a junction box. The house was built in 1985 so I think there should have been one. Anyway, there is a metal bar that is crossing the hole that conflicts with a new installation. I am prepared to cut this bar away to make room but I would like to know what it is before I create a new problem.
Does anybody have any idea what this is? And if I can cut it away without any regrets? The bar is shown in both of the attached photos. For background. This is an exterior wall. There is a stud located about 1" to the right of the existing cut out. There is a vent pipe on the left edge of the cutout. The metal bar appears to extend from the stud on the right generally in the direction of the stud on the left (outside of the photo). I have seen something like this as bracing for pipes in other locations of the house but in those cases they used copper pipe. Any suggestions would be appreciated. Derek
Hi guys. I'm Dan, and I'm in Knoxville, TN. I know running power to a shed is a very common topic here. I've been doing tons of reading and feel pretty comfortable with the requirements, but I have two questions I haven't been able to find a clear answer to.
First, my situation: I'm having a 10x16 shed built in my backyard, to be used primarily as a woodshop. I need more than a single circuit, so I know I need a subpanel and two grounding rods at least 6' apart, bonded to the subpanel with #6 bare copper wire. My house has 200 amp service, and the main panel is in the garage at the opposite corner of the house from where the shed will go, so it would be pretty inconvenient to run a feeder from, there. But there's an existing 100 amp subpanel in the basement, presumably installed when the previous owner finished the basement. I'll be running a 60 amp feeder from that subpanel to the shed. My total run will be something like 75', so I'm running #6 THWN for the two hots and neutral, and #10 THWN for the ground. I plan to bury it in 1.25" schedule 40 PVC, buried 18" deep. My first question relates to how I need to run the wire when it's not underground. The basement is finished with a drop ceiling, so I plan to run the feeder across the drop ceiling, out of the house, down to the ground (it's a walk-out basement), then underground the 26' to the shed. I assume it still needs to be in conduit for at least the part that runs up the wall of the house. But what about inside, when it runs through the drop ceiling to the panel? Does it need to be in conduit for the whole run? Or would I just staple the four wires to the joists or something? The other question relates to the trench. I've got a rain gutter downspout that discharges right at where the shed will soon be, so I'm running a 40' length of 4" PVC to pipe that water past the shed. It will be buried just about 6-12", just enough to run under the shed. Can I run the power conduit in the same trench (obviously, deeper)? Presumably I'd dig the 18" trench to the shed, lay the schedule 40, then add a few inches of dirt to bring it up to about 12" deep, and extend the trench past the shed at that depth, then lay the 4" drain pipe and backfill. Or do I need to dig two separate trenches? Is there a rule about how far apart they need to be if so? If anyone sees any other flaws or concerns with my plan, please do speak up, I want to do this right. Thanks! Dan
We need to have a new water line put in from the meter in the parking strip to the house. We've recently had a new electrical panel put in and the electricians pounded two grounding rods into the ground outside our house. Because of this, will the house be just as well grounded if we get plastic pipe as if we get metal?
I have a grounding question. I am installing 400a service to my new home. We ran 350MCM wire underground thru 3" conduit from the 2ndary terminal (moped) to the house into a 320A Cooper B-Line meter. From the meter we ran 2 sets of 4/0-4/0-2/0 thru the wall to 2-200a breaker panels ("standard practice", according to my electrical supplier). The ground wire (#4Cu bare) from the grounding rods comes up from the ground and we're curious if there has to be a special splice connecting the ground wire to each breaker panel or can we run thru one breaker panel to then next, say by connecting the ground wire to a ground bus on one panel and running that thru to the next with #4Cu bare or #6Cu in conductor. Different electricians are suggesting different methods and the electrical inspector is unsure, but seems to be leaning towards the "special splice". Any feedback would be appreciated.
I had a previous thread about bonding my inground pool. I had it done yesterday. I set up all the plumbing for my filter and I am going to wire it up tomorrow.
This pump was wired up once before and it is being moved. All the wiring was removed when the contractors were breaking up the concrete. It has a 25 amp breaker that I am going to replace with a GFI 25 amp breaker. I am going to wire it from the breaker box to a switch (1 foot from the box) to the receptacle about 45 feet away. I am going to use 12 gauge solid wire. I am not sure which would be better. Should I use 12/3 romex and use one as the ground or use 3 separate wires colored white, black and green. Also they had the green wire going to the ground bar in the breaker box. I guess I will attach the green(ground) wire to the ground bar and then run it to the green lugs on each receptacle. Also which types of boxes would be best to use metal or plastic. I am going to be using plastic pipe to run the wires.
I built a shed and wired it.
I used #8 direct burial from the house to the shed. I have a breaker in the house 15 amp for just my compressor. When i run the compressor i seems to drain power from everything else, ex: all light in the hose fad, my filter on the fish tank stops. Could some one help me figure this out and put a stop to it. Thanks Dak
can this be ground to the same copper pipe that has a ground from the service panel since that pipe is right there already supplying the tub .
thanks for the answers so far. i meant whirlpool .
I have a wall outlet I exposed recently. It was meant originally to supply an in-wall air conditioner (long since removed). The outlet is clearly a 120V, 20A fixture. The romex supplying it, however, has been marked in indelible ink by the installer: "220" on both sides of the wire sheath. The wire is 12/2 with ground. What did he mean by this? Could this really a 220V (or 240V) receptacle? Is that possible, using 12/2 and a standard 120V outlet? How do I verify what I've got?
All I want to do is relocate the box and replace the fixture, but the 220 notation sort of threw me. Does anybody have an idea what's going on here? I appreciate your help. I'm new here, so please try not to smack the rookie around too much.
I had posted a week or so ago about random afci's tripping aroung my house that is a year old. I am fairly convinced that it's a interference problem or something in my ground system. Outside my house there is a meter and next to it is a small breaker panel with a 200a breaker that feeds the panel downstairs. Outside there are 2 big black wires going to the ground bus. They go inside and one goes to the water pipe that comes in from outside. O can see where the other one goes. Is it important for me to put in a ground rod and run a big wire to the outside box? My las two new houses had them. I'll try to upload a pic of the outside box. Thanks
|