Help With Wiring New Bathroom
Hello Everyone-
I was hoping that someone would be able to help me connect the dots here as far as how to do the wiring for my new bathroom. To give you the basics... There is just one two wire power cable going to the bathroom. I have one single unit, that has two flip switches on it. - Switch 1 is to control the light. - Switch 2 is to control the fan. Then there is also one outlet, which I want to be always on, and not hooked up to any switch. Attached is a diagram of the individual components. Can someone help me connect the dots on how to wire this all up? Please let me know if you need any more details! Similar Tutorials
How to Lay Sod - The Right Way!
- Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
- This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
- If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ... Similar Topics From Forums
wanted to get feeback on my crude wiring diagram i put together for my small bathroom remodel. does it appear to be sound or am i way off base??
details: * 20A dedicated circuit * 12/2 wiring * outlet's will be GFCI * double gang box will contain: * timer unit for exhaust fan * double switch for heat lamp and lights * Ground wiring is not shown but each fixture/outlet/switch will be connected to ground wire * by calculations, the 34cu box is fine for the number of conductors/size of wiring. per box specs could handle 15/12g wires. * the scanner cut off the bottom part of the picture, the 2 lights on the right are fed from the same switch, neutral's connected together. F = Exhaust Fan L = Light HL = Heat Lamp T = Timer switch S = Switch H = Hot N = Neutral Wire Nuts are in the box connecting the pigtails Thank you for your input.
i have 3 switch sets in my house that are giving me absolute fits.
#1 kitchen switch, controls the light over the outside door Code: 3 sets of lines coming in, i cannot get this 3 line to work without tripping the breaker every time i turn the switch off #2 bathroom switches Code: power feed line same issue as the first set, flip the switch and trip the breaker (different breaker from the kitchen switch) #3 living room switch and plug controlled via switch Code: power feed line flip switch, trip breaker the switches i have are "1 pole" am i using the wrong switches for this job?
hi guys,
Im a 1st year apprentice sparks so pretty inexperienced! i have a job on during the week to wire a bathroom extractor fan in for my friend. He wants it to come on separately from the bathroom light. Theres a 2 gang switch outside the bathroom, one for landing lights other for bathroom. So im thinking of replacing this with a 3 gang switch for the fan. Im gonna take permanent feed from one of the two other switches ie(bathroom or landing) to the fan switch 'common' to power it, then also take a permanent feed for the fan from the 'common' side of this new switch as its a timer fan. Then switch feed from L1 on new switch to fan. And finally neutral from bathroom light fitting to fan. I know that these 3 cables going to fan have to be isolated at another switch before going to fan! Am I on the right track. Thanks in advance.
Hello,
I currently have one light switch which operates an outlet in one of my bedrooms. I want to add a ceiling fan that has independent switches for the fan and light - but I want to make sure i'm wiring it correctly and safely. Current (First Pic)- Live hot feeds into bottom of switch (bottom insert hole) and the all of the bedroom outlets (pig-tailed) tie into the bottom of the switch on the screw. Coming out of the top of the switch is one hot which feeds to a single outlet. All of the neutral and grounds are tied together. New Plan (Second Pic)- Remove the constant outlet hot from the screw, add a new hot wire to the top of new switch and run a wire up to the attic for fan. Add another hot wire from the bottom of that switch to the third switch and run another wire up to the attic for the lights. Re-connect the constant outlet wire to the screw of the last switch. Connect all the neutrals and all of the grounds together. At the top of the ceiling, connect the neutrals and grounds together with the fans neutral and ground. Connect the fan hot to the fan switch hot, and the fan light hot to the light switch hot.
Hi All,
Need to replace an old faulty two switch fixture in the bathroom (light and exhaust fan). Right now, each switch on the single fixture separately operates either the light or the fan, regardless of the position of the other switch. Want to keep things that way. Here is a picture of the old fixture's wiring: http://dl.dropbox.com/u/1179096/photo1.jpg To replace this fixture, I bought to the Leviton 5634 (design diagram he http://communities.leviton.com/servl...224%205634.pdf) Unfortunately, what is confusing me is the the different designs between the two fixtures and the fact that the original unit seems to have some kind of patch or cross over type wire connecting the top and the bottom switches (see photo link above). Any help/advice on how to wire this new fixture based on the picture of the current wiring configuration would be greatly appreciated. Thank you!!!
We had a pipe disconnect above the downstairs bathroom and the ceiling just about came down, so I decided since it was a hedious looking space, that it was a sign from the gods: Reno time!
Im now at the wiring stage. Originally there was a junction box with a light fixture out one side and a single pole switch(no ground screw...grnd wire attached to the box)on the other. Typical set up: white from switch marked "hot" or "black" at both ends, and spliced with the incoming power's black wire. Then remaining blacks are spliced together as are the remaining whites... grounded accordingly. What Im trying to do now is add a GFCI receptical to the mix. But Im having some trouble figuring it all out. NOTE: light fixture is not installed yet, just the wire for it with the ends capped off with a wire nut on each of the wires (Wht/Black/Grnd) First, whats in the walls: Circuits on a 15 AMP fuse with older (but not the oldest) 12/2 wire with a blue weaved fiber outside cover. Still looks to be in great shape. I've continued using newer, yellow (Lomex or Romex?) 12/2 from homedepot as I've read that you should not mix 14 and 12 together. All that is on the cicuit is 3 pot lights with 65w bulbs, single bulb on the stairway and what ever goes in the bathroom, so from my math, there should be plenty of room left on the circuit. What I've tried so far: A: I spliced the "hot"/"black" white wire from the switch to the incoming power's black, like before. Then I spliced all remaining blacks together with a wire nut, then the same with all remaining whites and then all grounds (did not attach any grnd wire to the Junction box). Result, Nothing. After switching on the power, I tested the GFCI with a voltage tester as well as the switch and got no read. B: Undid everything, re-spliced all like to like: all blck together, all white together..etc. Result: Fuse trips. Im no electrician, which I imagine is blatantly obvious from the above post, but I am following a Homedepot wiring manual, its just that what Im trying to do is not really addressed in the book... at least not directly. So I've been trying to figure it out by reading every single page, but Im still at a loss. I've attached a very basic diagram of what is there right now. Any advice would be most appreciated. Thanks in advance, John
Older house with the metal enclosed wiring has stumped me. I am attempting to add a second switch for a fan off existing light switch in bathroom. Existing wiring: W,B,R from panel, W,B to light. 2 white wire are tied together, two black wires to one contact and red to other contact on switch. Disconnected all wires and confirmed the black is live from panel. It seems to me the light is seeing power the entire time since the blacks are connected? I'm confused, please help. how do I add another switch onto this circuit? Thanks!
Im replacing what I thought was 2 single pole light switches but there is 3 black wires and one red. I hooked them up to the new switches but both switches worked the one light can anyone tell me how to connect the wiring?
This is kind of a complicated question, but I think I have figured out how to do it right. I wanted to run it by some folks here before going to the city code enforcer. See the attached diagrams for details.
I am planning a fairly elaborate lighting scheme for my home theater area, mostly because I plan for the theater automation to be a hobby for me. (I'm an electrical engineer) I want to have banks of lights that I could later choose to group differently onto dimmer switches. For example, I have six can lights. Some people I have talked to think I should dim the front four together and back two separately. Some think I should dim the front two together and back four separately. Some say I should dim them all together. So I decided I'd run each group of two cans to a junction box, run the switches to a junction box, and then wire the switches to the lights in the junction box - then I could later change it if I decided it should work differently. In addition, this would keep the junction boxes the dimmers were in free from extra wires, since I plan to buy nice dimmers that are fairly deep and would take more space in the switch boxes. And if I find that using switches differently would make it more intuitive, I can change which switch controls which lights easily after the fact. This would also allow me later to possibly control the lights with an automated system. There are some track lights and rope lights, as well as a couple receptacles that would all come back to the junction box where they'd be connected to the switches/dimmers. I am bringing in power from two circuits to balance the lighting. I plan to put some of the lights on one circuit and some on the other. The second circuit has some other stuff on it already, so it has less load left over, so most stuff will go on the first circuit. Also to save on wiring and make running wire easier, I was planning to use 14/3 wiring where possible. Any given 14/3 wire would always be connected to only one of the circuits (no shared neutrals). The attached files show my exact plan for each circuit. Note they both share the junction box in the upper right corner of the pictures, they also share the switch banks. This allows me to decide which switches control which lights, as well as decide which lights will be powered on which circuit to balance them properly. Note that the track lights are each 2 circuit track, that's why I'm running 14/3 to each. See the attached files for circuit #1 and circuit #2 I am running 14/3 NM to the switches. I was planning to have two switches share one 14/3 cable. I am also running 14/3 to each group of two light groups that I want to control separately. I've also attached a diagram from the perspective of the junction box. I also attached an example circuit on how I plan to use the 14/3 wire. Here are some other decisions I made: - The junction box will be PVC 8x8x4 (256 cu. in.) All the wires coming into the box add up to 70 cu in. so the box should be plenty large. - All the grounds from both circuits will be tied together - The neutrals for both circuits will always be kept completely separate (NO shared neutrals) - No 14/3 wire will ever carry power from more than one circuit (this would violate the shared neutrals anyway) Even though this is kind of elaborate and for hobby, I want to be sure to do it safely and up to code. Does anyone see anything wrong with my plan? Thanks, Daniel
When repairing a light switch I came across this wiring in a supposed 3-way setting in my kitchen. Two Single Pole Double Throw switches controlling a single light fixture.
Check out the quick and dirty wiring diagram showing the way these are connected. I believe there should be a 14/3 between the two switches right? All I see is 14/2 coming in and a 14/2 going across to the other switch, and then a 14/2 going to the light. And why are the neutrals cut and wire capped? This doesn't make sense to me, but the light does work from both switches. Any insight will be greatly appreciated. Cheers! |