More Faucet/water Shocks
Hi all,
I have read a few posts here about others having problems with receiving a shock while touching the faucet or water from the faucet in certain rooms. Today I experienced this problem in my kitchen. I was able to narrow the problem down to one breaker on my box, specifically one set of outlets. My question is can a faulty outlet cause this to happen? I currently have the breaker in question flipped off until I can replace the outlet and see if that fixes the problem. There haven't been any changes to the electrical or plumbing in quite a while. This happened completely out of the blue. Any advise that you might have would be greatly appreciated. Jess Similar Tutorials
How to Lay Sod - The Right Way!
- Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
- This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
- If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ... Similar Topics From Forums
if a 110v receptacle is located near a water faucet on the inside of a building, does it need to be GFCI protected? no sink involved.
Hello, what could be the cause of the kitchen sink faucet stream feeling a slight tingling sensation when the garbage disposal is running?
Can't be good, I know! Possibly a grounding issue? 200 Amp service w/ two subpanels. House is about 25 years old. Thanks for any help how to start troubleshooting.
Hi all, this is my first post, so...my kitchen was just renovated and the electrical outlets are on the walls and I wanted them in plugmold under the cabinet. Why didn't it happen? Long story, but I'm doing it myself now. The electrical receptacles are on 2 separate circuits with a gfci receptacle on each and neither circuit has a receptacle outside the kitchen where I can put the gfci's, so I'm putting gfci breakers in the panel instead. I've run into a different problem on each circuit that'd like some advice on.
Circuit 1: this is a 20 amp circuit. I have to plug this circuit's neutral wire into the gfci breaker, but I couldn't see which neutral wire matched the hot wire (buried in mess of wires) and I don't have a continuity tester so I just pulled one neutral at a time (tedious) until the circuit failed, but it never failed. So I did this again for every neutral...same result. This circuit shares a few boxes with other circuits so I'm wondering if the neutrals on different circuits are tied together somewhere, and if so I'm pretty sure, but not completely, that that's not going to work with the gfci breaker. So I didn't install that gfci breaker since I'm not confident it would actually gfci (yep i verbified gfci). What do you think? Circuit 2: this is a 20 amp circuit. This circuit currently has the refrigerator, gas stove and range hood, and then a gfci in front of 3 electrical receptacles, which already sounds bad since I thought the kitchen receptacles required 2 dedicated circuits. I replaced that breaker with no problem, but it tripped after a few minutes and continued to trip every few minutes. I haven't changed anything else on that circuit yet and it's never tripped before, but now it is, so I put the old breaker back for now. The current gfci receptacle is only protecting the 3 outlets since the appliances are ahead of it. I know you wouldn't normally want the appliances gfci protected, so do you think the refrigerator motor may be a problem? Do I need the appliances on a separate circuit? What would you suggest I do? Thanks, and if you're wondering "why all the effort?", it's partly because I'm meddlesome, partly because I'm bored, and partly because the backsplash tile is to be on showcase, not the electrical receptacles.
i just recently moved back into my home and found that all of my exterior power outlets seem to be dead. something must've happened while i was out of the house, but i've no idea what.
should be simple right? a breaker somewhere? interior outlets are all fine, no other apparent electrical issues. i've been to the breaker box, and there are no breakers specifically marked for the exterior outlets, and all of the breakers appear to be set/active. anyone have any suggestions as to where to look for the problem? adv-thanks-ance for your thoughts!
I am new to the forum so kindly bear with me. I live in Mesa, AZ and have just had a PEX repipe done to bypass my copper hot water lines. (God don't ask! A real problem here with slab foundations. I already had my kitchen jack hammered once. It is NOT pretty!).
It seems really odd to me that just because it is a dedicated circuit that code would not require that circuit to be GFCI protected. I have a dedicated 20 amp duplex 12 AWG wire outlet under the sink and it is within a few inches of the water lines. The outlet serves a switch for the garbage disposal and serves my dishwasher which is always hot. Now that I have all my maple cabinets pulled out I thought I might change the outlet to a GFCI just to be safe. I have a ground wire, a red wire, a black wire and a white wire. As it is dedicated I think I should use the LINE sided instead of the LOAD side but I am not sure where the wires should go. Could someone give me info on this? It would be greatly appreciated. Thank you.
Today I was fixing the water valve to the washing machine, and to get access to the water line, I had to disassemble an outlet. To my shock (no pun intended), I discovered that some moron bootlegged the outlet by connecting neutral and ground together.
Now I'm concerned that I may have this elsewhere in the house. What is the best way to test for this? Obviously I will see 120 V from hot to ground in any case, so that doesn't work. Continuity between neutral and ground is normal, because they are connected at the main panel; I measured the resistance between neutral and ground at an outlet close to the main panel, and it was virtually zero. But that doesn't meat it's bootlegged. I don't really want to take each outlet apart. And even if I do that, how would I know that the moron didn't connect ground to neutral somewhere inside a wall? Thanks,
I have a small 19 gallon water heater in a small garage space, that was installed by some questionable handymen a few months back. I just had the plumbing and septic finished so tested the hot water, only to find the element was already burned out.
I noticed however, that this 120v unit is wired via 10 gauge wire to a 30 amp double breaker. This is questionable because I thought a 120v appliance would be wired to a single pole on the hot wire and run neutral to the neural panel area. My question is, can I run the hot wire out of one side of the double breaker without safety issues, or should I definitely replace it with a single pole breaker? I would normally not question the work, but everything these guys did already had to be adjusted, so I'm only naturally assuming this may need to be also. If its safe, I would like to simply things and just connect the one hot and leave an open space in the other half of the double pole... Is this possible? Thanks for your advice-
So I have an outlet in my living room which has recently stopped working. I checked it with the voltmeter and it shows 90V output instead of the 120V AC which it should be normally. The fuse that this is on is fine. I also disconnected the plug behind the covers and tested at the wires themselves and it's still 90V. So the problem is not at the outlet side but either in the wall or somewhere else?
Is there a way to debug this or is this even a more common problem? Thanks!
I have no power on the wiring on a GFCI outlet. I tested the breaker and it has power. I also tested all other GFCI outlets and they are working. What could be my problem?
I have a home that I only use from time to time. At Christmas one of the GFCI outlets kept tripping. This outlet has a TV/reciever/cable box/xbox/lights, etc. on the load side. When I reset it, everything would be OK for 20 minutes or so, then it would trip. I did not have time to investigate the problem so I just left it. When I returned a week or so ago, the outlet was tripped and would not reset. As soon as I pushed the reset button in, it would pop back out. I replace the GFCI outlet but that did not help. I removed all load outlets and inspected them. Everything looked OK. Anyone have an idea. The strange thing to me is that the problem seemed to get worse over time. (I.e. it stayed reset for 30 minutes at Christmas and now it will not reset at all). Ideas? Thanks in advance.
|