Can 14 Gauge Wire Be Used On 20 Amp Circuit?
I am redoing my basement, and i am making the electrical runs for the recessed lights in the ceiling. I am using 14 gauge wire, and i have 16 recessed lights with 65 watt bulbs in them, however they are rated at 75 watts max. assuming someone after us may put in the max bulb, the total watts would be 1200, equaling 10 amps. When all of the new wiring is done, i am going to have an electrician connect the circuits to the circuit breaker (using 15 amp breakers) however since i am not comfortable doing this myself, and i would like to use the lights now, can i connect them to the existing 12 gauge wire (this will not overload the breaker... i already checked what else was plugged in to the electrical outlets).
to recap: The power draw will only be 10 amps at MAX. capacity existing wiring is 12 gauge/ 20 amp breaker electrician WILL connect 14 gauge wire to breaker using 15 amp breaker *THIS WILL BE TEMPORARY* Similar Tutorials
How to Lay Sod - The Right Way!
- Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
- This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
- If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ... Similar Topics From Forums
I have a covered (rafters, decking, shingles, etc) screen room out back. It used to have a single light, which I wanted to replace with a ceiling fan with light kit, independently switched. So I bought this fan/light dimmer: http://www.lowes.com/pd_69955-539-S2...d=10151&rpp=24
I checked the wire at the old light, and as it was 14-2, I removed it and replaced it with 14-3. It wasn't until after I spent 3 hours crawling around the attic on my stomach running the new line that it hit me....the circuit is on a 20 amp breaker. The line running to the switch, and a jumper running from it to 5 wall outlets in the living room, is all 12-2. The new line runs straight from the switch to the fan box, with no other outlets. So while I doubt it is up to code, it seems like it should be ok. The fan/light won't pull anywhere near enough power to overheat the 14 gauge line, and if there is an actual fault, it should trip the 20 amp breaker anyway. I would very much like to hear from the experts. Running the 14-3 was a serious pain in the butt, and replacing it with 12-3 would be just as bad. So if this is safe, I'd rather not replace it. But if I am risking a fire, it is obviously worth the hassle.
I posted this in the woodworking forum and I got a ton of rants so please spare me that please. I'm not an idiot and I intend on completely turning off all power before attempting anything.
So I've been researching adding a couple of electrical outlets to my garage (where the panel is). I want to run a new 120v outlet for the tablesaw (older craftsman 113 series) so that it is on it's own circuit and a 240v outlet for a grizzly G1029z2 DC on it's own circuit as well. What amp 120 circuit should I add for my tablesaw? Will a standard 15a breaker be fine? What amp 240 circuit should I add for my DC? The motor plate states 12 amps and the manual says the electrical is a minimum circuit size of 20. Should I just install a 20amp circuit or go with larger circuit? Need recommendations on the gauge of wire to use on each circuit.
Hi, I have a fluorescent light I'd like to remove and add a tracklight.
Luckily it's in the basement with an unfinished ceiling. here's the circuit map as is now: 1. breaker to fluorescent light.... connections inside 2. fluorescent light to switch at the top of the stairs 3. switch to the light in the stairwell. This terminates the circuit. The wiring is all 14/2 I'd like to replace the the fluorescent light with a track light, but I'm not sure how to continue the circuit to the switch in the stairwell. Is it safe to... 1. bring the cable from the breaker to the junction box. 2. connect the black wire with the black wire on the light AND the black wire leaving the box to the switch in the stairwell using a marette. 3. connect the white wire with the white wire on the light AND the white wire leaving the box to the switch in the stairwell using a marette 4. connecting a 6 inch bare 14 gauge wire to the box ground screw, then using a marette, connecting it with the ground wire from the cable entering the box as well as the one leaving and also the ground wire from the light. Will this work and is it safe?
I'm trying to fix a problem with a track light installment over the a bar I've just put in. I've done it before. never had issues. but this particular problem is driving me nuts. It just defies logic. The electrician who actually installed the associated dimmer switches with this dining room area was called as it seems it may be a flaw with his wiring, but he's blown us off and I have to try and solve this myself.
This is how it's all set up. I've been rehabbing our home from top to bottom, and converted our old kitchen into a dining area. Within this dining area are four sets of lights, all controlled from one box containing four dimmer switches. I set up all the new wiring and installation of the lights in the ceiling, and we paid an electrician to come in, check everything out, set up the multiple switches, and connect it all to the board. It's all new copper wiring from beginning to end, as I didn't want to connect or splice in to the old aluminum wiring that was in place. All the new wiring and lights are on a dedicated 15 amp breaker. Three of the sets of lights were set up to be available from the day the electrician came around. The fourth, for the track light over the bar, was left hanging from the ceiling capped off and with the switch off, as I still had work to do installing an overhead wine rack, under which the track was going to be set. Two days ago I finally got around to putting the track up, but after setting it in place and connecting the power up the lights wouldn't work. I took the lights out to our kitchen, where I installed another track light system some time ago, plugged one of the lights in, and it worked just fine. I then went back to the bar area and used a spare track, then a spare connector, to see if I could isolate the fault, yet neither of the items provided a solution. Now here's the weird bit - every time I tried checking the system out, I'd get 120 volts showing from the wiring and from the track when I'd test with the multimeter. But the second I'd put a light into the track, the multimeter would drop to zero on the voltage reading on either the wiring or the track. Take the light fixture back out, and the voltage would pop back up. Inserting the light was thus completing some kind of odd loop. It wasn't just one light - I double checked by grabbing working lights from the kitchen track and inserting them into the other track - the same problem would pop up. Finally, having come to the conclusion that there was nothing wrong with the track at all, I took the whole assembly over to a nearby wall outlet, used some spare electric cable to connect up to the appropriate slots - presto, the light came on! I even double checked all this by grabbing another light fixture destined for our bathroom, and tried connecting it to the wiring over the bar. Nothing. Yet as with the track light, the minute I took it over to the wall outlet and connected it, the light worked. So everything logically points to the fact it has to be something to do with this individual circuit, right, because a) the light fixtures work when plugged into another circuit and b) the other three dimmers and lights hooked up in the same box work fine and draw power from the same wire cable/breaker combination. The only things left that I can think of is that the electrician has either wired the dimmer switch up incorrectly or that there's some kind of flaw inside the switch itself. Does this make sense? A friend also told me to double-check to make sure that the black wire feeding power to the light was indeed the hot wire, and it is. If I touch it with the black test lead from the multimeter and put the red one to the neutral I show 120 volts. If I keep the black test lead on the black wire and put the red test lead to the ground - I also show 120 volts. A final point. I know I'm not overloading the circuit - not even close. With all four dimmers maxed and every light on - including the test light on the track - I'd only be drawing 8 amps on a 15 amp breaker, besides which I'm only using one set of lights while I'm working on this problem anyway. This is a dedicated circuit, so there's no additional power being drawn away by something else. So how am I getting 120 volts from this wiring, according to my multimeter, yet it won't light up ANYTHING and keeps giving off the indication that some kind of loop or short is being created every time I actually plug a light into the track? It's got me totally stumped. Anyone have any ideas?
I have a small 19 gallon water heater in a small garage space, that was installed by some questionable handymen a few months back. I just had the plumbing and septic finished so tested the hot water, only to find the element was already burned out.
I noticed however, that this 120v unit is wired via 10 gauge wire to a 30 amp double breaker. This is questionable because I thought a 120v appliance would be wired to a single pole on the hot wire and run neutral to the neural panel area. My question is, can I run the hot wire out of one side of the double breaker without safety issues, or should I definitely replace it with a single pole breaker? I would normally not question the work, but everything these guys did already had to be adjusted, so I'm only naturally assuming this may need to be also. If its safe, I would like to simply things and just connect the one hot and leave an open space in the other half of the double pole... Is this possible? Thanks for your advice-
I had a previous thread about bonding my inground pool. I had it done yesterday. I set up all the plumbing for my filter and I am going to wire it up tomorrow.
This pump was wired up once before and it is being moved. All the wiring was removed when the contractors were breaking up the concrete. It has a 25 amp breaker that I am going to replace with a GFI 25 amp breaker. I am going to wire it from the breaker box to a switch (1 foot from the box) to the receptacle about 45 feet away. I am going to use 12 gauge solid wire. I am not sure which would be better. Should I use 12/3 romex and use one as the ground or use 3 separate wires colored white, black and green. Also they had the green wire going to the ground bar in the breaker box. I guess I will attach the green(ground) wire to the ground bar and then run it to the green lugs on each receptacle. Also which types of boxes would be best to use metal or plastic. I am going to be using plastic pipe to run the wires.
Now I have a 20 amp breaker at the circuit box that has older two wire, ie black and white no ground. This cable looks to be in good shape. This services several overhead lights in bedrooms. I need to tie into this to create overhead lights in the bathroom and hallway. Can I replace the 20 amp breaker with a 15 amp breaker, and then use 14-2 cable to connect the bathroom and hall lighting? I do not know if the present older cable is 12 or 14. I assume it is 12 since it has been tied into this 20 amp breaker before I bought the house.
Thank you to all who help.
Hello
I recently upgraded my old fuse panel with a circuit panel. One of the circuits contains mostly lights and also my furnace. The wire on the lights are 14/2 and the breaker is a 20 amp breaker. Can I replace the 20 amp breaker with a 15 amp Breaker or do I need to change all the wire. Help Thanks
I have 3 bedrooms on 15 amp circuits, 14 gauge wire. Original wiring is one bedroom is on one circuit and the other 2 bedrooms on another circuit. The wall switches in each switched the top half of an outlet in each room. I converted the wire at the wall switch to a 110V feed from the outlet and ran 14/3 from the switch to the ceiling for a ceiling fan. I replaced the outlets since the jumper was cut to isolate the 2 plug ins for switching. Is this whole scenario code compliant?
I want to run a new 12/3 to wire a room added on the back of the house. One circuit will be 6 wall outlets. The other will be a ceiling fan and 4 recessed cans. Can I add 2 outdoor lights-using standard outdoor bulbs-to the same circuit as the ceiling lights? Do I use the wall switch(box properly sized) as the junction for the outlet wiring and feed to wall switch for outdoor lights?
|