15 Amp Simplex Receptacle

I have a 20 amp circuit with two 15 amp duplex receptacles on it; can I also put a 15 amp simplex receptacle on this same circuit?
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

When you install a dedicated circuit, say for a washer or refrigerator, does the NEC require the receptacle to be a simplex rather than a duplex ?



Arky
      
If you have a 20 amp circuit going to your bathroom vanity, can you have two 20 amp receptacles on it, one a GFI receptacle and the other a standard 20 amp receptacle wired to the load terminals of the GFI receptacle ?



Or does the code require each receptacle to be a GFI on its own circuit ?



Arky
      
i have just installed 4 cans controlled by a dimmer switch using 14/2 wire and plan to hook into a 15A circuit. The easiest wire for me to hook into this circuit is on the load side of a receptacle that goes to another receptacle. can I cut the wire that goes between receptacles and split the hot wire so it goes to the new recessed cans ( same for the white wire) and then on to the receptacle as previous?

Thanks

Tom
      
Hi all, this is my first post, so...my kitchen was just renovated and the electrical outlets are on the walls and I wanted them in plugmold under the cabinet. Why didn't it happen?  Long story, but I'm doing it myself now.  The electrical receptacles are on 2 separate circuits with a gfci receptacle on each and neither circuit has a receptacle outside the kitchen where I can put the gfci's, so I'm putting gfci breakers in the panel instead. I've run into a different problem on each circuit that'd like some advice on.



Circuit 1: this is a 20 amp circuit.  I have to plug this circuit's neutral wire into the gfci breaker, but I couldn't see which neutral wire matched the hot wire (buried in mess of wires) and I don't have a continuity tester so I just pulled one neutral at a time (tedious) until the circuit failed, but it never failed. So I did this again for every neutral...same result. This circuit shares a few boxes with other circuits so I'm wondering if the neutrals on different circuits are tied together somewhere, and if so I'm pretty sure, but not completely, that that's not going to work with the gfci breaker.  So I didn't install that gfci breaker since I'm not confident it would actually gfci (yep i verbified gfci).  What do you think?



Circuit 2:  this is a 20 amp circuit.  This circuit currently has the refrigerator, gas stove and range hood, and then a gfci in front of 3 electrical receptacles, which already sounds bad since I thought the kitchen receptacles required 2 dedicated circuits. I replaced that breaker with no problem, but it tripped after a few minutes and continued to trip every few minutes. I haven't changed anything else on that circuit yet and it's never tripped before, but now it is, so I put the old breaker back for now. The current gfci receptacle is only protecting the 3 outlets since the appliances are ahead of it. I know you wouldn't normally want the appliances gfci protected, so do you think the refrigerator motor may be a problem?  Do I need the appliances on a separate circuit?  What would you suggest I do?



Thanks, and if you're wondering "why all the effort?", it's partly because I'm meddlesome, partly because I'm bored, and partly because the backsplash tile is to be on showcase, not the electrical receptacles.
      
Is there any limitation as to how many receptacles can be protected by one GFCI receptacle?  For example, can I start the circuit with a GFCI and have another 8 receptacles downstream from it?
      
Hello!



In a house I recently bought I have a strange situation.



There is a three way switch on one side of the wall with two sets of wires coming in:



Red, Black, White

Black, White



and then one stray Black that goes to the duplex receptacle on the other side of the wall (on the OUTSIDE of the wall!  Clearly an afterthought.)



Into the receptacle goes this strange black single wire from the light switch and the usual black and white wires + ground wire.



I went to change the ugly receptacle to a decora and now it doesn't work, though I'm not 100% sure it worked before.



I've wired the new receptacle as I remember it being wired before, any idea what is wrong? 



I've attached a diagram!



Thanks in advance for any input.
      
In most homes I've noticed that there is always a receptacle right next to the electrical panel and is usually the only thing on that circuit. 

Why is this?

And is there any reason you couldn't add additional items to that circuit, for instance, if you were finishing the basement?



Thanks in advance.
      
New appliances coming in. No change in service, so I believe that existing wiring can be considered grandfathered. Please correct me if wrong. BTW: we're under 2005 code in my locality, but I go with 2008.



Currently, the kitchen is wired all 15-amp except for non-counter-top receptacles. (I know, opposite, and wrong, but that's the way it is)





Can dishwasher and disposal be on same 15 amp circuit? (This will be a new circuit, so perhaps I need to run 20-amp?)


Current range wiring is 3-wire on a 40 amp breaker (3-pole). Can I still utilize a 3-prong receptacle here?


Does the kitchen wiring have to be upgraded to provide for 2 SABC (currently, only 1), and 20 amp?



      
I have a single receptacle with 12/2 on a GFI (20 amp). I ran a 3 wire (14 gauge) to my other two receptacles and put a tandem breaker in the panel. Should I wire the receptacles as single receptacles on individual GFI's or split receptacles? They are more than a meter away from the sink. Also I have read the two 15 amp circuits should be on separate phases? How do I insure this?  Thanks gentlemen!
      
Hi,



Forgive me if this has been covered elsewhere - a cursory check didn't

bring up an answer, but maybe I didn't search on the right thing...



I've got to replace a baseboard heater that was located under a receptacle.



I was first thinking this is covered by the "grandfather" clause, but a bit more checking has me confused - it looks like maybe the NEC doesn't specifically prohibit this (maybe they do in the newest code book), but pretty much all manufacturers now seem to specifically say not to do this, so it would seem to be prohibited.



So what do you do?  Here's a couple of pics of where I have to put this unit:



http://www.rkgphotos.com/recent_stuf...er_corner2.jpg

http://www.rkgphotos.com/recent_stuf...er_corner1.jpg



a 1500W unit is what should go here.  just pulling the receptacle/putting on a cover plate means there's gonna be more than 12 feet between receptacles along this wall.



Its also complicated by this being both an outside wall and a common element so I didn't want to butcher it up completely.



It seemed like I could: 1) use 2 heaters with a gap under the receptacle (though the spacing kind of sucks for this), 2)pull the receptacle, put on a cover plate and forget about it (practically not a problem but violates the 12 foot rule), 3) use the receptacle box as a J box and run a line down to where the heater is and use one of those funky receptacles you mount to one end of the heater, or 4)??



Anyway, suggestions/observations would be greatly appreciated.



Thanks,

rkg

(Richard George)