Short Wires

I NEED TO UPDATE MY ELECTRICAL PANEL. I FIND THAT SOME OF MY NEUTRAL AND GROUND  AND HOT WIRES ARE A BIT SHORT OF REACHING THE GROUNDING  BAR AND FOR THE BREAKERS. HOW DO I EXTEND THESE WIRES? CAN I ADD PIG TAILS TO EACH WIRE, USING WIRE NUTS?



Thanks in advance for any help or reply
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Was switching out a panel and was trying to get wires bent so that they would be short enough to reach the breaker and the neutral wire reach.  But when pulling on the neutral wire to bunch it up under the lug I kinked the wires.  One worse than the other.  I was thinking I should just cut the wire and go straight up into the lugs instead of bending like this or should I leave it alone?



Was a long day and I just decided to find out what others though about this.




      
Hey,

I'm located in Ontario/Canada and I'm in the process of installing some recessed lights in my uninsulated basement. I was going through the electrical code and noticed that in an 8in^3 electrical box, it is only permitted to have 2 wires and 2 wire nuts.



I have 3 wire nuts (ground, neutral and hot) and two wires coming into each switch.



It seams odd that the light box would not be sized correctly considering its CSA approved. Have any of you come across a similar problem ?



As a side note, I'm also finding it hard to jam 6-8in of cable and 3 wire nuts in this small box !
      
I built a free standing garage with main power tapped from the home breaker box.  The contractor pulled 4 wires via a conduit to the freestanding garage panel which supplies lights, a garage door, and two 20 amp outlets.



Everything worked well initially, but about 1 week ago one section of the lights in the building went out.  The contractor came out and found that one of the two hot wires in the garage panel was only seeing 100 volts and that went down if anything else was turned on.  He swapped one of the ground wires for the bad hot wire and everything now works. 



What would cause a situation like this where the hot wire apparently had a voltage loss?  Is it safe to continue with the fix where the faulty wire is now the ground?



Thanks in advance!
      
Installing a 4-ton condensing unit outside (240V, 1 ph, MCA= 26A, MOP= 45A).  There will be a HVACR rated 45A breaker at the panel.  Plan to install the 60A non-fused disconnect with GFCI recepticle (GE U065NA1010) next to condensing unit.  Plan to use #8 wire since distance from panel is 80 feet, but unsure of the number of wires.  How many conductors will be required since the disconnect will have a 120V GFCI recepticle.  Will I need 2 wires (2 hots and 1 ground) or 3 wires (2 hots, 1 neutral, 1 ground)?  I'm thinking #8 wire with 3 conductors (2 hots, 1 neutral, 1 ground).
      
Hello All,



I'm about to "re-locate" some existing breakers and wires into a subpanel and have a few questions.



1) My existing hot water heater is wired with 2 conductor w/ground wiring (30 amp, #10 wire). Is this still Code compliant or do you have to have 3 conductor now as with dryers?



My existing dryer also has 2 conductor w/ground wiring (installed in 1999).



If I relocated it or the hot water wires/breakers to my new subpanel will they require me to upgrade to current code (3 conductor, if applicable)? The subpanel will attach to the Main Load Center which is where those breakers/wires are currently attached.



Main question is will I be grandfathered with existing wiring in only relocating the breakers/wires to subpanel?  I'm not relocating the appliances or recepticles themselves.



2) I have 3 conductor w/ground wires for my cook top. It only requires 2 conducter w/ground however. They wired the ground/neutrals together but has flexible metal conduit running to the cook top itself. Should I remove the ground and bond it to the metal conduit?



Thanks, Ralph
      
4 gang switch box. power into this box. All wire is 12 Guage.



Neutrals and hots are easy to nut together, 5 at most in 1 nut.



But what about the ground wires? There will be 9 total ends that need to be connected, 9 seems like alot under 1 wire nut.....or is it? lol



Can i make up 2 sets of grounds and use a jumper between the 2 wire nuts?



Do they make a wire nut for 6 wires?
      
Hello!  I am trying to hook up this antique pendant lamp and the cord it comes with has only 2 wires inside.  They are both smooth and white, no stripes or ridges to tell which one is hot or neutral.  And what should I do with the third one coming out from the ceiling?  Thanks in advance for your advice.
      
Hello! Great help here. I did a search and could not find a solution to my problem so I had to make a new thread.



I just purchased this house and it is a bit of a fixer upper. one side of the house has no power. This looks to be a sub panel? and it is on the side of the house with no power. I was wondering if anybody could help with the wiring of this panel? The main box is just on the outside of this box.







This looks like an old box and I can not see where to wire the ground/common wires. There are 2 bars under the breakers and both have a black wire connected to them.
      
Help!  We decided to raise the ceiling in our kitchen for some new taller cabinets. We have 30" cabinets with a 7' drop ceiling. By taking out the drop ceiling we can go to an 8' ceiling with 36" cabinets.  We just had the ceiling taken out and now I see I got a problem!



This is a 2 story home, the wall in question is a load bearing wall (runs through the center of the house) The main breaker panel is in this wall (the panel opening is in the adjacent family room)



As you can see in the photos I cannot extend the wall up because all of the home wiring is in the way!  I expected I might have to run longer wires but not this. 



Some ideas we've thought about...

notch the double 2x4s (not sure how much I need to notch or allowed to)



build a cove (box) and leave the wires like they are (might be an eyesore in our new kitchen)



put up a large crown moulding along the entire wall (would be the only crown moulding in the house)



extend the ceiling up 6-7" instead of 12" (should leave enough room for wire to stay)



I'm leaning to the notching option if I can find a way to reinforce that section.



Any ideas?



thanks!
      
wanted to get feeback on my crude wiring diagram i put together for my small bathroom remodel. does it appear to be sound or am i way off base??



details:



* 20A dedicated circuit

* 12/2 wiring

* outlet's will be GFCI

* double gang box will contain:

* timer unit for exhaust fan

* double switch for heat lamp and lights

* Ground wiring is not shown but each fixture/outlet/switch will be connected to ground wire

* by calculations, the 34cu box is fine for the number of conductors/size of wiring. per box specs could handle 15/12g wires.

* the scanner cut off the bottom part of the picture, the 2 lights on the right are fed from the same switch, neutral's connected together.



F = Exhaust Fan

L = Light

HL = Heat Lamp

T = Timer switch

S = Switch

H = Hot

N = Neutral

Wire Nuts are in the box connecting the pigtails



Thank you for your input.