Ceiling Fan

I would love to put a ceiling fan in my living room but my husband isn't anxious about climbing into the attic to anchor it. He's not really that handy. I was wondering if a fan could be hung like light fixture, by a chain. Obviously, the ceiling would have to have a joist to put the hook into so the fan could hang. The chain and cord would be loosely hung near outlet so it could be plugged in.



.
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I was in my attic today doing some work when I noticed a bare twisted copper wire that ran along a ceiling joist.  All along it was charred wood and charred  fiberglass insulation.  Luckily the fire it caused did not sustain itself and I was able to find the problem.  I then traced the wire and figured it originated in my breaker box (although I could not determine exactly where in the box).  It then ran across my attic alongside a ceiling joist and down into a wall ending up connecting to my water meter.

  Several months ago,  the electric company was restoring power to my area and ended up sending a power surge into my house taking out an oscillating fan, a toaster and a GFI outlet.  Last winter, I also had to have my electric meter pole replaced by an electrician after a tree branch took it out during an ice storm.

  I was wondering if one of these events could have caused the ground wire to heat up or something else entirely is going on?  I am suppose to have a company blow in  insulation soon and I need to figure this problem out.  Any help would be appreciated.  Thanks.
      
just wondering if someone can give me a quick answer.  I currently have 7 receptacles and 3 lights on one circuit.  the receptacles are in the living room and the lights are in the basement.  I have just installed 6 recessed lights in the living room. does anyone think that that is too much to add to the circuit.  not much gets plugged in in the living room    T.V.  couple of lamps dvd player, occasional vacuum cleaner.
      
I have 3 bedrooms on 15 amp circuits, 14 gauge wire. Original wiring is one bedroom is on one circuit and the other 2 bedrooms on another circuit. The wall switches in each switched the top half of an outlet in each room. I converted the wire at the wall switch to a 110V feed from the outlet and ran 14/3 from the switch to the ceiling for a ceiling fan. I replaced the outlets since the jumper was cut to isolate the 2 plug ins for switching. Is this whole scenario code compliant?
      
We are revamping our patio area a bit which is off of our sun room.  I was wondering if anyone has ever heard of installing in-ceiling speakers in soffits?  If so, could you provide some tips in doing so? Thanks!
      
With a hard wired LED closet light fixture, can it be wired like an undercabinet fixture? clamp the wire to the light and push the excess wire into the ceiling?

 

Or can i install an outlet on the ceiling and use the plug in style lights?

 

Im going to install a switch outside of the closet so there will be 1 wire going to the light.



What is the best way to do this?
      
Okay, I am fairly new to wiring but its not the wiring I am wondering about.  It is running the wires.  I have 2 rooms in my house, 2 story and an attic, on the main floor that doesn't have any overhead lighting, only can use floor or table lamps right now.  The ceilings are about 10 feet tall.  There are outlets in the room so I do have power I can tap into for the lighting, but how do I go about running the wires up into the ceiling?  I do know I have to cut the hole for the lighting but will i have to put cut flaps in the drywall where ever there is a brace to drill holes to run the wires.  I am going to go from the middle of the ceiling straight back to the wall and then down to the switch that I will put in and then down to the outlet to tap into for the power.  I am just trying to do this the easiest way to minimize any drywall repair that will be needed.  Any help or suggestions from anyone is greatly appreciated and if you have questions please ask and I willl try to answer them.
      
I am installing a ceiling fan for my mom and the wiring has me a little confused. I posted pictures below of the ceiling fan wiring and the light fixture wiring. Just need to know how to connect the two together without burning down the place. Thanks in advance






      
I only have one outlet in my living room and I need another one for sure. What are some ways I can do this?  There is not another outlet on the other side of the wall, we had a electrician come add a light with switch and he said something about closing off a line behind the switch box.  Is it possible to re-open that line? We also have a attic which I was told at homedepot is easy to do if you have another outlet in the next room you don't use. Any help is greatly appreciated!!
      
Hello,



I currently have one light switch which operates an outlet in one of my bedrooms.  I want to add a ceiling fan that has independent switches for the fan and light - but I want to make sure i'm wiring it correctly and safely.



Current (First Pic)- Live hot feeds into bottom of switch (bottom insert hole) and the all of the bedroom outlets (pig-tailed) tie into the bottom of the switch on the screw.  Coming out of the top of the switch is one hot which feeds to a single outlet.  All of the neutral and grounds are tied together.



New Plan (Second Pic)- Remove the constant outlet hot from the screw, add a new hot wire to the top of new switch and run a wire up to the attic for fan.  Add another hot wire from the bottom of that switch to the third switch and run another wire up to the attic for the lights.  Re-connect the constant outlet wire to the screw of the last switch.  Connect all the neutrals and all of the grounds together.



At the top of the ceiling, connect the neutrals and grounds together with the fans neutral and ground.  Connect the fan hot to the fan switch hot, and the fan light hot to the light switch hot.
      
After my electrical panel was replaced I noticed that my ceiling fan light was dim.  My fan works fine on all speeds but the light is dim.  It is a Hampton Bay model MKV with a remote control.  Wondering if it could be a relay problem with the unit??