Shops To Buy Electrical Equipment/tools In Budapest/hungary
Anyone have any experience with buying stuff like electrical outlets or tools in (central) Budapest preferably? Looking for shops to visit, preferably in Budapest. Going there this summer. Appreciate any answers, also from anyone knowing of any decent Hungarian webshops for the same.
Cheers, dogs Similar Tutorials
How to Lay Sod - The Right Way!
- Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
- This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
- If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ... Similar Topics From Forums
I'm building a whole house everything system. It is a sixteen zone system with full AV distribution, 9 security cameras, about 70 speakers, ten 9.1 surround sound amplifiers, 6 PCs, KVMs, loads of networking gear, two dss, bluray, roku, squeezebox, NVR server, NVR viewer, etc. There are air conditioners in the Liebert MCR racks. The headend contains three 42U racks. Two of the racks are for AV equipment and the third rack is for the PC equipment.
Here is a detailed list of all the equipment and their electrical needs: http://dl.dropbox.com/u/70589/MillerPlan.xls You will see two tabs on the spreadsheet: Equipment and Cabinets. These contain very detailed information on all the devices going into the three racks. You will see that I specified 14 electrical circuits. I have already purchased all the equipment except for the "APC UPS 280 watts" and "Furman power conditioners". If anybody experienced with residential systems with requirements like this could give me feedback on the electrical requirements and my proposed design it would be great, all feedback is welcome!
I'm new to the forum and I don't mess with electrical issues. I leave it to the pros. My question, I'm looking at buying an older home. It is upgraded to a 200 amp panel, has 3 prong outlets, but the owner said he never ran a gound from the box. What are the pitfalls / safety hazards of not having grounded outlets? thanks,
First off, I have read a majority of the posts concerning this subject and they have been very helpful and answered many questions, but I still have a few.
I am wanting to run power to a detached shed that is around 100 feet from the house. However, due to the location of my main panel and the easiest route to run the power, I am looking at running cable about 270 feet. I measured it out to exactly 263 feet, but figured it would be best to go longer. I am wanting to run at least 60 amps to the shed, as I won't be using it for nothing more then power outlets (basic power tools) and lights. Here are my questions: 1) What cable would be best for such a long distance run? 2) Would a 60 amp subpanel be sufficient for this job. I am looking at only 4 circuits: 1 for internal outlets, 1 for lighting, 1 for motion sensor light outside and 1 for external outlet. I am looking at the following panel: http://www.homedepot.com/Electrical-...&storeId=10051 I have seen some marked 70 amp and wondering if they make a difference: http://www.homedepot.com/Electrical-...&storeId=10051 3) Also, I will be installing a 30 amp RV connector circuit from my main panel to the where I park my Camper Trailer, which is a run of about 75 feet. What would be the best cable for this sort of run under ground? Can I run both cable together in the same conduit until I junction if off to where I will be installing the plug for the camper? 4) Would the following be the circuit breakers to use: 60 amp - http://www.homedepot.com/h_d1/N-5yc1...&storeId=10051 30 amp - http://www.homedepot.com/h_d1/N-5yc1...&storeId=10051 I think that is it for now. Thanks in advance for all your help!!
Greetings all.
This is my first post here, I hope it goes well. My name is Joe and I have searched Google. and this forum for my answer but have not been able to find a definitive answer to my question. I have seen many replies talking about getting a tone generator or a line tracer but my experience is that tone generators are for Data and phone cables rather than electrical cables and the line tracers I've found online all seem to be about tracing the line back to the breaker panel so without knowing more I'm hesitant to purchase a line tracer in case it cannot do what I want. My dilemma is very likely very simple to anyone with electrical experience so I hope it's not too trivial for this crowd. I have recently purchased a house that is over 120 years old and have a motion sensor light on the porch that is supposedly connected to a switch inside but does not turn on. I've opened the wall plate and used a voltage indicating pen to see where the electricity is. In this case there are two light switches, one that has lines that have been spliced and another that supposedly leads to the porch light according to a long time tenant in that unit. It all looks like a bit of a mess and the connections don't make sense. In this scenario the black cables have the electricity and the white cables complete the circuit. The switch to the porch light has a black cable coming from the top of the box going to the switch and a white cable connected to the other screw that comes from splitting the white cable from the other switch. What I would like to do is know which cables in that wall box correspond to the cables to the porch light. Can anyone give me an idea what I should do? Do I need something like the Amprobe advanced wire tracer (http://www.professionalequipment.com...0/wire-tracer/) and can it do what I need, or is there something simpler I can do? All help is appreciated. Thanks Joe
Hi, I recently moved into a 1954 house with a 20amp electrical system, not the old fuse type, but there are no ground wires.
I removed an old light and replaced it with a light fan combo. As I removed the old light (after turning off the breaker) I noticed from the ceiling that there were 2 white wires tied together with a wire nut and 2 black wires, one attached to the white wire in the light and the other attached to the black one from the light. Feeling this was wrong and should be black to black, white to white, (even knowing full well the light was working fine before I disconnected it) I wired the fan the way I've always wired fan lights, white to white, blue and black to black. (again, knowing full well the light was working the other way). Turned breaker on then powered on switch. POP at the switch, breaker switched off. I reworked it back to the way it was before with whites tied off, black to white, black and blue to black, turned it back on and viola, things worked fine. (I know, duh... Right???) 2 questions from this experience... 1. Why would the 2 whites be tied off with only black wires used? And 2. It seems that one of the light switches in the same circuit as the blown one is now working soft. In other words, it used to make the normal click noise when turned on/off but now it just moves softly up and down without the click. Could I have damaged something when I mis-wired?
Live in California... Pool and backyard remodel
Running a new 100Amp line from the main electrical house box that is 200amp to the new Hayward ProLogic Pool sub panel for the pool equipment. Is that #2 wire or #4? The pool installers are telling me that they need 50 amps for the 3 pumps, 2 pool lights and gas heater that I have. The reason that I'm running 100amps to the sub panel and only using 50amps for the pool is because there is electrical going to the overhang and backyard that can be controlled by a remote that talks to the ProLogic sub panel. I have a overhang/BBQ area that has 17Amps for the refer and BBQ, a water feature which is about 15-20 amps, 2 ceiling fans for the overhang, low-voltage lights for the overhang, low-voltage landscaping lights for the backyard only. I think that is about it. Inspector is telling me that I need a GFCI at the sub panel. Is this a 100amp GFCI prior to the sub panel being wired? Or does each piece of equipment need a GFCI? I am having a licensed electrical contractor do this, but I'm just trying to do my homework because some of them are not knowledgeable about pool wiring... (BTW, I had a licensed contractor out yesterday, to give me a bid and he said that they didn't make a 100amp GFCI, which of course I did see on the internet, not using him!!)
I know nothing about car stereos, but I had a crazy thought the other day and figured someone here on this board would know home electrical stuff and also car stereo (electrical) stuff.... so here goes....
How difficult would it be to "rig up" a car stereo (or, actually, an in-dash video player/receiver) in a house, hardwired in? I assume (admittedly, without researching) that the foremost issue is that car power is DC, so the first problem would be getting a transformer to take 110VAC to whatever the stereo required in DC, right? As far as speakers - are car speakers and home speakers essentially the same, as far as the signal sent to them from the receiver/amp/radio? Or are they a different capacity (resistance ohms or something)? Could you use home speakers (say, small in-ceiling type speakers, like you typically see sold for home theater surround usage) with a car stereo? Finally, do these systems typically have standard audio and video inputs in the rear (component, composite, S-video, headphone-jack type plug)? I know they typically have an "aux" input on the front (for video game systems, iPods, MP3 players, and whatnot) but do they have connections on the back where it would be out of view when permanently connected (for connection from the satellite box)? I had this crazy idea that I would love to install one of those car stereos with the slide-out, pop-up TV screen into my bathroom, and have the sound wired to ceiling speakers. If I built a cabinet with a mounting frame that would hold it in place, could this work? I am not looking for some high-end sound system that will blow me away and rock the house, nor do I care about a beautiful HD picture on the TV... I just want to have a small TV and a radio/audio receiver at the vanity area that I could hear with the shower running or whatever, and car systems like this are way less expensive than buying a small LCD TV and a stereo receiver (plus I can't find a receiver small enough). Plus, you would get the added benefit of the TV "disappearing" when not in use. Obviously, this would take some rigging - transformers and all - but can anyone clue me in on the feasibility?
So we just bought a circal-1930s house, and one very large project looming is redoing the eletrical. The house has a mix of BX, cotton-wraped romex, and some very cracked romex running around the house. combine that with some very odd additions for outlets, bad light switch placement, it's just going to be a large project.
My father in law, a licensed electrician, has promised to do the rewiring of the house this summer. The problem is I plan to do some major renovations in the coming years (namely the kitchen). I am already drawing up floor plans now so I can stategically think of where to put needed outlets, but should they be installed at this time? Is it worth the headache to install new outlets now and put them in their proper locations when the reno comes?
Greetings,
I am looking to wire a sub-panel in my barn to support a general workshop. Loads would include standard woodworking tools (including 220V table saw), welding, air compressor, etc. The house has 200AMP main breaker and minimal in-house loads. Dryer is gas, Oven and cooktop are gas. Water heater is off the oil furnace. I think the biggest single load is the well-pump and/or fridge compressor. We do have sporadic toaster oven, hairdryers etc. Otherwise its just lights, ceiling fans, flat-panel tv, stereo... We had 4" conduit installed to the barn, so there is plenty of room to pull a big cable. The entire run from the house panel to the barn totals around 155' (probably less, but rounding up) My questions a Can I pull a 100AMP sub-panel from my main house panel as described? Would 4/0,4/0,4/0,2/0 aluminum service entrance cable be a good choice for this run? Could I do it with something lighter? Could I put an additional sub-panel in the garage (about halfway to the barn) by interrupting the run? The garage subpanel would have a 220V plug for possible welding and/or electric car charging. Would this require a separate run? Are there any other considerations I should be thinking about in planning this? Thanks for any thoughts you can share on this! Cheers, pete
I'm planning to add some deck stair lighting this spring/summer to our newly finished deck, and knew I was going to go with low voltage. Then it had me thinking...I would also like to run low voltage in place of where we had originally planned to place solar lights along our sidewalk that's beside the deck (lights here will be embedded in river rock). Anyways, I know to steer clear of the HD and Lowe's brands, but I don't really know where to begin for quality lighting. I want the transformer to be rather large since it will have to handle larger runs, and be able to handle additional lights that may be added on down the road. Plus I want a timer/photo sensitivity built in. I was curious if anyone had any specific brands to recommend? I did see Kichler recommended in a few searches I made here, but any others?
Any general recommendations would be appreciated as well (i.e. buying a kit vs buying the transformer, wire, lights, connectors, etc. separate). |