Vent Hood

Morning people. I'm installing a chimney style range hood for a friend of mine and he wants me to leave the plug wire on instead of hard wiring it. This would be permanent. Reason being is so he could remove it himself at a future date to tile the wall. This means I'd have to put a receptacle on the wall next to the vertical duct and it would be hidden behind the vent stack cover. It wouldn't be easily accesable so I'm thinking that's a code violation anywhere you go. From what I found it's a grey area. Any thoughts? Thanks
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Installing a new cook top; the original plug was installed at the vent hood.  How do I move the plug to underneath the cabinet without tearing out the wall?
      
Our new range hood states is should be a dedicated 15 amp circuit. Is okay to put it on a 20 amp or would that violate code?
      
Hi,



Upgraded my cordless Dustbusters at home with the new CHV1410 model, it works great except what was my surprise when I found out Black & Decker is no longer making Dustbusters that charge automatically on the wall mount.



Instead (and I was told this by their customer support when I called them) ALL the new models have a DC plug. I hate these, not only do you have to take the extra step of plugging in the vaccum each time when you hang it on the wall... mine being mounted down inside a bathroom cabinet, this makes it a pain hunting for the wire... but these DC plugs are weak, I've seen them give out with daily repeated plug-in-unplug use.



I decided to wire up the old style wall charger on the new vaccuum, using a few of the parts from the old dustbuster. I figured out how to do it (its not as hard as it sounds) but I was wondering about the polarity of the charger. If you hook the DC charger up to the wall mount backwards, will it destroy the battery? How do you verify which wire goes on which side.



Thanks for any advice - jeffpas
      
How do I replace a range hood for an over the range microwave?
      
Hi,



Forgive me if this has been covered elsewhere - a cursory check didn't

bring up an answer, but maybe I didn't search on the right thing...



I've got to replace a baseboard heater that was located under a receptacle.



I was first thinking this is covered by the "grandfather" clause, but a bit more checking has me confused - it looks like maybe the NEC doesn't specifically prohibit this (maybe they do in the newest code book), but pretty much all manufacturers now seem to specifically say not to do this, so it would seem to be prohibited.



So what do you do?  Here's a couple of pics of where I have to put this unit:



http://www.rkgphotos.com/recent_stuf...er_corner2.jpg

http://www.rkgphotos.com/recent_stuf...er_corner1.jpg



a 1500W unit is what should go here.  just pulling the receptacle/putting on a cover plate means there's gonna be more than 12 feet between receptacles along this wall.



Its also complicated by this being both an outside wall and a common element so I didn't want to butcher it up completely.



It seemed like I could: 1) use 2 heaters with a gap under the receptacle (though the spacing kind of sucks for this), 2)pull the receptacle, put on a cover plate and forget about it (practically not a problem but violates the 12 foot rule), 3) use the receptacle box as a J box and run a line down to where the heater is and use one of those funky receptacles you mount to one end of the heater, or 4)??



Anyway, suggestions/observations would be greatly appreciated.



Thanks,

rkg

(Richard George)
      
I have a battery operated 12v emergency light located in my basement. It has two lamps on it. I would like to remove one of them and place it upstairs in my dining room to cover that and the living room. I have some old 14/3 SO cable lying around and wondered if you guys thought if it would be acceptable to use this. Also, can I run this in the wall cavity as long as my terminations are inside the box where I mount the light? Is there any part of the code that covers this or any violation of the code?



Thanks,

Rick
      
I am in the process of installing a submerisble pump into my well, but I have a few questions I'd like answered first.



The pump is a 1HP, 230V pump with 8.2amps and KW 0.75.  It is rated at 12/2 w/ ground. 



1) Is there any reason I shouldn't install a 230v wall mounted switch to turn this on/off if I want to kill the power.  For now a pump start will control it for my irrigation system, this would just be in addition if I ever wanted to shut things down and not have to rely on using the breaker, which I understand shouldn't be used as a switch.



2) What about installing this on a plug, so that I can plug it into a receptacle vs. hardwired.  (*I'll explain my reason later)



3) My understanding is 12gauge wire is rated for 20amp, but it looks like the owners manual calls for a 25amp fuse.  Should I use 20amp or 25amp?



*The reason I ask about the switch and the plug is because I plan on using some wiring that is already in place.  I already have 12/2 w/ground installed in the location of the pump start.  It is currently wired for 110v as it was placed there for a 3/4hp jet pump I planned on installing, but ended up going with a cased well instead, so I figure why not utilize the existing wire, but switch it to 220 instead of 110.  Basically, swap the 20amp 110v switch out for a similar rated 230v switch and replace the receptacle with a 230v receptacle and just plug this pump in. 



I question the use of the plug because I thought I had read somewhere it was ok to use one, but when unpacking the pump last night, I thought I read never to install it on a plug, so now I'm unsure.  Why would they not want it on a plug?  I guess it's not a big deal as I can always run wire into the j-box, but I hate using pigtails if I don't have to.



Thanks for any info on this...heading to the parts store in a while to grab the fuse and anything else I need.
      
I was going to put this in this thread  Junction box in stud wall behind drywall?  but, decided to start a new one.



Two nights ago while sitting in my kitchen the can lights in my soffits above my cabinets suddenly went out. At first I thought my daughter or her boyfriend was messing with me and reached around the corner and flipped the switch. Nope. Tried the other switch near me and nothing. Everything else in the kitchen worked.



Thinking tripped breaker for a moment...nope other lights work on the circuit. Can't be 6 CFL's burnd out at the same time. Hmmmmm?



Background:

Kitchen was remodeled 12 years ago. Drywall was in good shape so not removed. Added circuits for Fridge, Microwave, Garbage disposal, Stove (gas),Dishwasher, range hood, and countertop recepts. None of these are tied to lights. Original task lighting was 4' tubes over countertops above cabinets. Remodel added sofits and can lights from these two feeds



Started tracing circuit path to look for loose/broken wire. Found no power at lights. Checked power at breaker...Good. Follow wire to kitchen, no junctions. Wire disapears up into wall below the switch area. Check for power at switch box. Yep, power there. Power off and pigtail Neutral/hot  wires at a can light together. No continuity on the load side of the switch circuit. Broken wire somewhere between the switch and the lights. Fortunaly there is an attic space above the kitchen. Unfortunatly, it is a short headroom ~3' or less and full of blown ihn insulation. In I go to trace the wire.  after about 10 min up there I found the burried junction box. At some time in the past there used to be a single light in the center of the "U" shaped kitchen cabinets. This was abandoned and the box was drywalled over...still in the location for the light hookup so the cover was not readily accessable. found a tightly twisted Ground, Neutral and Hot with nuts. All looked good untill I Started messing with them. found that one of the hot leads had broken right at the insulation on the wire. Looking at it closer I could see some arc burn at the break. I am thinking that when the handy hack that did the job nicked the wire he did not know or care and tristed it together anyway. It took over, to my best guess, 20 years for it to fail.



Moral... It can happen
      
I have 2" grey pvc conduit running from my basement underneath a patio and terminating vertically from the ground a few feet past the edge of the patio (in the dirt).  I want to install an outlet on the stone wall at the edge of this patio.  I do not know how to properly return the wire from that open 2" vertical conduit back to the wall a few feet away.  I assume I need a junction box on the existing conduit, but can't find one with a 2" inlet.  I would like to keep the connections buried if possible, return with a smaller conduit to the wall and up to a mounted outlet box (weatherproof).  Any suggestions about how to manage the conduit connections from the vertical pipe?



Tom
      
Hi all, this is my first post, so...my kitchen was just renovated and the electrical outlets are on the walls and I wanted them in plugmold under the cabinet. Why didn't it happen?  Long story, but I'm doing it myself now.  The electrical receptacles are on 2 separate circuits with a gfci receptacle on each and neither circuit has a receptacle outside the kitchen where I can put the gfci's, so I'm putting gfci breakers in the panel instead. I've run into a different problem on each circuit that'd like some advice on.



Circuit 1: this is a 20 amp circuit.  I have to plug this circuit's neutral wire into the gfci breaker, but I couldn't see which neutral wire matched the hot wire (buried in mess of wires) and I don't have a continuity tester so I just pulled one neutral at a time (tedious) until the circuit failed, but it never failed. So I did this again for every neutral...same result. This circuit shares a few boxes with other circuits so I'm wondering if the neutrals on different circuits are tied together somewhere, and if so I'm pretty sure, but not completely, that that's not going to work with the gfci breaker.  So I didn't install that gfci breaker since I'm not confident it would actually gfci (yep i verbified gfci).  What do you think?



Circuit 2:  this is a 20 amp circuit.  This circuit currently has the refrigerator, gas stove and range hood, and then a gfci in front of 3 electrical receptacles, which already sounds bad since I thought the kitchen receptacles required 2 dedicated circuits. I replaced that breaker with no problem, but it tripped after a few minutes and continued to trip every few minutes. I haven't changed anything else on that circuit yet and it's never tripped before, but now it is, so I put the old breaker back for now. The current gfci receptacle is only protecting the 3 outlets since the appliances are ahead of it. I know you wouldn't normally want the appliances gfci protected, so do you think the refrigerator motor may be a problem?  Do I need the appliances on a separate circuit?  What would you suggest I do?



Thanks, and if you're wondering "why all the effort?", it's partly because I'm meddlesome, partly because I'm bored, and partly because the backsplash tile is to be on showcase, not the electrical receptacles.