Bathroom Electrical Layout Questions

wanted to get feeback on my crude wiring diagram i put together for my small bathroom remodel. does it appear to be sound or am i way off base??



details:



* 20A dedicated circuit

* 12/2 wiring

* outlet's will be GFCI

* double gang box will contain:

* timer unit for exhaust fan

* double switch for heat lamp and lights

* Ground wiring is not shown but each fixture/outlet/switch will be connected to ground wire

* by calculations, the 34cu box is fine for the number of conductors/size of wiring. per box specs could handle 15/12g wires.

* the scanner cut off the bottom part of the picture, the 2 lights on the right are fed from the same switch, neutral's connected together.



F = Exhaust Fan

L = Light

HL = Heat Lamp

T = Timer switch

S = Switch

H = Hot

N = Neutral

Wire Nuts are in the box connecting the pigtails



Thank you for your input.
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Hi All,



Need to replace an old faulty two switch fixture in the bathroom (light and exhaust fan). Right now, each switch on the single fixture separately operates either the light or the fan, regardless of the position of the other switch. Want to keep things that way. 



Here is a picture of the old fixture's wiring: http://dl.dropbox.com/u/1179096/photo1.jpg



To replace this fixture, I bought to the Leviton 5634 (design diagram he  http://communities.leviton.com/servl...224%205634.pdf)



Unfortunately, what is confusing me is the the different designs between the two fixtures and the fact that the original unit seems to have some kind of patch or cross over type wire connecting the top and the bottom switches (see photo link above).



Any help/advice on how to wire this new fixture based on the picture of the current wiring configuration would be greatly appreciated. Thank you!!!
      
I am trying to replace a rocker switch that runs my Panasonic bathroom exhaust fan with a programmable switch that allows me to run the thing automatically several times a day to help suck moisture out of the condo (it's a 1962 condo with concrete walls, aluminum windows, and no central air).



I initially bought a GE SunSmart Timer but it requires a neutral, which I don't think I have. I understand there are some other switches like Intermatic ones that don't require neutrals.



I don't think I have a neutral because the condo is old and I don't see a white wire in the box, but what's strange is that I do see an unconnected orange wire in there. Does anybody know what that could be? Image is attached. Essentially there are 2 blues, 1 red, 1 black, and 1 orange (unconnected) in there. The only thing I can find about orange wires is something called a "high leg delta" circuit, which seems reasonable because it's supposedly used to control fans and lights off the same circuit, which is exactly what's going on here (one can light, one heat lamp, and one fan).



Any ideas?
      
hi guys,



Im a 1st year apprentice sparks so pretty inexperienced! i have a job on during the week to wire a bathroom extractor fan in for my friend. He wants it to come on separately from the bathroom light.



Theres a 2 gang switch outside  the bathroom, one for landing lights other for bathroom. So im thinking of replacing this with a 3 gang switch for the fan.



Im gonna take permanent feed from one of the two other switches ie(bathroom or landing) to the fan switch 'common' to power it, then also take a permanent feed for the fan from the 'common' side of this new switch as its a timer fan.



Then switch feed from L1 on new switch to fan. And finally neutral from bathroom light fitting to fan. I know that these 3 cables going to fan have to be isolated at another switch before going to fan!



Am I on the right track. Thanks in advance.
      
I have an outdoor light fixture that I am trying to replace.  The house was built ten years ago.



When I removed the original lamp, I noticed one of the two leads was wired to the ground, and one was wired to the black wire, which is hot per my current sensor.  There are three wires in the box - black, ground (bare copper), and white or neutral, all from a single romex cable.  Unfortunately, I do not recall where the white was when I removed the original. 



I wired the new lamp per the instructions, something I have done many times before - black to black, white to white, and bare copper ground to ground.  Nothing.  The lamp and bulbs are brand new, and I have tried four separate bulbs.  I checked the black and neutral with my current sensor and with the switch on and the lamp installed this way, both show as hot. With the lamp not installed, the switch on, and the wires disconnected only the black shows as hot.  The switch is single pole, and appears to be wired correctly with a black to each screw on one side and a copper ground on the other.



Assuming the new fixture was bad, I reinstalled the old fixture correctly -  black to black, white to white, and bare copper ground to ground.  Still nothing. No light, and I confirmed the bulb is good by putting it in another lamp.   The only way to get it to light is to connect the neutral in the lamp to the bare copper ground.



I capped the wires, turned the circuit back on, and identified all the outlets, switches and fixtures on the same circuit.  I opened every one of them up (four lights and eight outlets) and found three (one switch and two fixtures in another room) where multiple commons connect.  All were properly connected.  My outlet tester shows all outlets as "correct".  I found no instances of grounds connected to commons or vice-versa.



Any ideas?  Is it proper to wire this thing the way I found it?



Thanks for any and all advice!
      
Hello Everyone-

   I was hoping that someone would be able to help me connect the dots here as far as how to do the wiring for my new bathroom.   To give you the basics...



There is just one two wire power cable going to the bathroom.

I have one single unit, that has two flip switches on it.

- Switch 1 is to control the light.

- Switch 2 is to control the fan.

Then there is also one outlet, which I want to be always on, and not hooked up to any switch.



Attached is a diagram of the individual components.



Can someone help me connect the dots on how to wire this all up?  Please let me know if you need any more details!
      
I'm trying to fix a problem with a track light installment over the a bar I've just put in. I've done it before. never had issues. but this particular problem is driving me nuts. It just defies logic.  The electrician who actually installed the associated dimmer switches with this dining room area was called as it seems it may be a flaw with his wiring, but he's blown us off and I have to try and solve this myself.



This is how it's all set up. I've been rehabbing our home from top to bottom, and converted our old kitchen into a dining area. Within this dining area are four sets of lights, all controlled from one box containing four dimmer switches. I set up all the new wiring and installation of the lights in the ceiling, and we paid an electrician to come in, check everything out, set up the multiple switches, and connect it all to the board. It's all new copper wiring from beginning to end, as I didn't want to connect or splice in to the old aluminum wiring that was in place. All the new wiring and lights are on a dedicated 15 amp breaker. Three of the sets of lights were set up to be available from the day the electrician came around. The fourth, for the track light over the bar, was left hanging from the ceiling capped off and with the switch off, as I still had work to do installing an overhead wine rack, under which the track was going to be set.



Two days ago I finally got around to putting the track up, but after setting it in place and connecting the power up the lights wouldn't work. I took the lights out to our kitchen, where I installed another track light system some time ago, plugged one of the lights in, and it worked just fine. I then went back to the bar area and used a spare track, then a spare connector, to see if I could isolate the fault, yet neither of the items provided a solution. Now here's the weird bit - every time I tried checking the system out, I'd get 120 volts showing from the wiring and from the track when I'd test with the multimeter. But the second I'd put a light into the track, the multimeter would drop to zero on the voltage reading on either the wiring or the track. Take the light fixture back out, and the voltage would pop back up. Inserting the light was thus completing some kind of odd loop. It wasn't just one light - I double checked by grabbing working lights from the kitchen track and inserting them into the other track - the same problem would pop up. Finally, having come to the conclusion that there was nothing wrong with the track at all, I took the whole assembly over to a nearby wall outlet, used some spare electric cable to connect up to the appropriate slots - presto, the light came on! I even double checked all this by grabbing another light fixture destined for our bathroom, and tried connecting it to the wiring over the bar. Nothing. Yet as with the track light, the minute I took it over to the wall outlet and connected it, the light worked.



So everything logically points to the fact it has to be something to do with this individual circuit, right, because a) the light fixtures work when plugged into another circuit and b) the other three dimmers and lights hooked up in the same box work fine and draw power from the same wire cable/breaker combination. The only things left that I can think of is that the electrician has either wired the dimmer switch up incorrectly or that there's some kind of flaw inside the switch itself. Does this make sense?



A friend also told me to double-check to make sure that the black wire feeding power to the light was indeed the hot wire, and it is.  If I touch it with the black test lead from the multimeter and put the red one to the neutral I show 120 volts. If I keep the black test lead on the black wire and put the red test lead to the ground - I also show 120 volts.



A final point. I know I'm not overloading the circuit - not even close. With all four dimmers maxed and every light on - including the test light on the track - I'd only be drawing 8 amps on a 15 amp breaker, besides which I'm only using one set of lights while I'm working on this problem anyway. This is a dedicated circuit, so there's no additional power being drawn away by something else.



So how am I getting 120 volts from this wiring, according to my multimeter, yet it won't light up ANYTHING and keeps giving off the indication that some kind of loop or short is being created every time I actually plug a light into the track? It's got me totally stumped.



Anyone have any ideas?
      
Am doing a bathroom reno and installed a new fan. Original switch was a simple on off single pole. I want to install a DewPoint condensation fan switch that will turn on automatically at a certain moisture level.

The new switch as 4 wires. green ground, red fan, black power, and white neutral. I know the ground, but how do I hook up the neutral and fan to the existing fan set up?

There is a double pole light switch in the same box that has a couple wires to it, and there is a mass of whites that I am not sure where they go



Can I hook up the neutral somewhere else, or put it with the fan like a single pole? What do I do with this?



In the attached picture the switch on the right is the 2 pole light switch and on the left is the fan switch that I hope to replace.



Your Advice is appreciated
      
Hello,



I currently have one light switch which operates an outlet in one of my bedrooms.  I want to add a ceiling fan that has independent switches for the fan and light - but I want to make sure i'm wiring it correctly and safely.



Current (First Pic)- Live hot feeds into bottom of switch (bottom insert hole) and the all of the bedroom outlets (pig-tailed) tie into the bottom of the switch on the screw.  Coming out of the top of the switch is one hot which feeds to a single outlet.  All of the neutral and grounds are tied together.



New Plan (Second Pic)- Remove the constant outlet hot from the screw, add a new hot wire to the top of new switch and run a wire up to the attic for fan.  Add another hot wire from the bottom of that switch to the third switch and run another wire up to the attic for the lights.  Re-connect the constant outlet wire to the screw of the last switch.  Connect all the neutrals and all of the grounds together.



At the top of the ceiling, connect the neutrals and grounds together with the fans neutral and ground.  Connect the fan hot to the fan switch hot, and the fan light hot to the light switch hot.
      
hello

I am dealing with what seems like a strange issue with a single pole switch, and I am royally baffled even after reaching out to someone a little more knowledgeable than me.



Yesterday: Replaced with a single pole switch with an identical one that I painted (for decor reasons). Two wires were going into the old, and the same 2 wires are attached to the new one. However, the light it controls fails to come on despite light bulb being good, and outlet located 4 feet below the switch fails to operate. With voltmeter in hand I tested voltages.

At the switch: 3 wires feed into it, all whites capped together, and 2 of the 3 blacks (A,B,C) are hot with 110. A is hot and was/is connected to one of the terminals of the single pole switch. B and C (hot) are capped together with a jumper that goes to the other terminal of the single pole switch. So I am royally baffled as to why a switch would be wired with 2 hot wires going into it. I swear it has been like that since we bought the house a year ago, and the light worked fine. I simply replaced the switch with the same wiring, and now it doesnt work. I even touched both hots (A and C) independently to wire B which (using common sense) should be the load wire to the lamp, but the lamp did not come one.



Other outlets in that circuit do not work either. They get 110 to line and ground, but not across the outlet.



I hope I was clear in explaining, and I hope someone can possibly shed some light so I can resolve this.



Thank you
      
Hey,

I'm located in Ontario/Canada and I'm in the process of installing some recessed lights in my uninsulated basement. I was going through the electrical code and noticed that in an 8in^3 electrical box, it is only permitted to have 2 wires and 2 wire nuts.



I have 3 wire nuts (ground, neutral and hot) and two wires coming into each switch.



It seams odd that the light box would not be sized correctly considering its CSA approved. Have any of you come across a similar problem ?



As a side note, I'm also finding it hard to jam 6-8in of cable and 3 wire nuts in this small box !