How To Replace A 2 Gang Switch Box With A 3 Gang Box?

What would be the best way to remove the existing box?
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

4 gang switch box. power into this box. All wire is 12 Guage.



Neutrals and hots are easy to nut together, 5 at most in 1 nut.



But what about the ground wires? There will be 9 total ends that need to be connected, 9 seems like alot under 1 wire nut.....or is it? lol



Can i make up 2 sets of grounds and use a jumper between the 2 wire nuts?



Do they make a wire nut for 6 wires?
      
hi guys,



Im a 1st year apprentice sparks so pretty inexperienced! i have a job on during the week to wire a bathroom extractor fan in for my friend. He wants it to come on separately from the bathroom light.



Theres a 2 gang switch outside  the bathroom, one for landing lights other for bathroom. So im thinking of replacing this with a 3 gang switch for the fan.



Im gonna take permanent feed from one of the two other switches ie(bathroom or landing) to the fan switch 'common' to power it, then also take a permanent feed for the fan from the 'common' side of this new switch as its a timer fan.



Then switch feed from L1 on new switch to fan. And finally neutral from bathroom light fitting to fan. I know that these 3 cables going to fan have to be isolated at another switch before going to fan!



Am I on the right track. Thanks in advance.
      
I am currently remodeling a bedroom in my home for a new baby.  I have gutted the room and am replacing all the electrical and adding new recessed lighting.  The room will also have a ceiling fan, along with the recessed lighting.  I am looking for a single gang light switch that will operate the ceiling fan independently of the recessed lighting, with a dimmer for the recessed lighting.  I don't have room for a double gang box where the switch is currently placed, as there is a closet in the way.  Is there such a thing as a switch that will operate the ceiling fan and it's lighting on a normal on/off switch, with a dimmer that can independently control the recessed lighting?  I have checked with the local big box stores and everyone has told me I will have to run two switches.  Is this the case?  Any info would be greatly appreciated.  Thanks in advance.
      
I have 2 light switches in my entry and need to add a 3rd. So…I removed the old 2-space metal box and will be replacing it with a 3-gang old-work box.



      The issue I’m anticipating having is: The old knob & tube wires coming in aren't very long. As the locations of the openings for the wires in the 3-gang box is a bit different than the old box, I’m worried that the wires now won’t be long enough to now reach the light switches. So, my questions are...



 

   If I need to add 6” or so to some of these wires, is it okay to just splice a new piece of 14-gauge wire onto them?? I simply didn't know if you're allowed to do this.


If so, is this just a matter of using a plastic twist cap to connect them…with everything being done inside the new box?


  Thanks so much for your advice.
      
I have an older house I which I need to replace/update some romex wiring. I was planning on turning of the power to the circuit, remove the devices from the wall box and then remove the box. I was hoping to use the old wire to pull the new wire. My problem is how to remove the old wire from the cable staple so it will be lose to use for pulling. Any suggestions?
      
Have a 2 gang box with two outlets in it.  The side opposite the stud protrudes from the wall 1/4 or so.  It pushes in too so when you plug something in it is spongy.  Any fix other than replacing it?
      
I've see the drawing for lights/chandelier over bath tub (in forum) but I think this refers to USA. See drawing. #3 is gfi with 1, 2, 9, 4 being tapped off 3. # 3 would be dedicated from panel at 15 amps. #5, 6, 7, 8, 10 would be another 15 amp dedicated 15 amp non gfi.



Questions: A) Can I have chandelier over bathtub?

B) Are switches too close to bathtub? If yes can switch be outside the bathroom

C) Because only switch 4 is gfi protected can I still use a 3 gang box?





D) Kitchen: Any rules regarding distance from sink for a non gfi switch controlling lighting?





Input regarding Ontario electrical code refering to above would be appreciated.



I have uploaded a compressed drawing of bathroom.



Jan

janluthe@hotmail.com
      
wanted to get feeback on my crude wiring diagram i put together for my small bathroom remodel. does it appear to be sound or am i way off base??



details:



* 20A dedicated circuit

* 12/2 wiring

* outlet's will be GFCI

* double gang box will contain:

* timer unit for exhaust fan

* double switch for heat lamp and lights

* Ground wiring is not shown but each fixture/outlet/switch will be connected to ground wire

* by calculations, the 34cu box is fine for the number of conductors/size of wiring. per box specs could handle 15/12g wires.

* the scanner cut off the bottom part of the picture, the 2 lights on the right are fed from the same switch, neutral's connected together.



F = Exhaust Fan

L = Light

HL = Heat Lamp

T = Timer switch

S = Switch

H = Hot

N = Neutral

Wire Nuts are in the box connecting the pigtails



Thank you for your input.
      
Hi everyone,



I'm pretty new to the whole homeowning/do it yourself lifestyle, and have a question about the light fixture in my kitchen.  Recently 2 twisted cfl bulbs went out, probably within 1-2 days of each other, and I am having a hard time figuring out how to replace the bulb.  I believe the lights in my kitchen are considered recessed lighting.



So when the first light went out, I hastily grabbed my step ladder and tried to twist the bulb out.  I should have looked more closely at the fixture because when I started to twist, the bulb popped in my hand.  No big deal, just a bunch of debris all over the place.  I looked at the fixture and it said I should pull straight down to remove.  Doh!  The second light went out a day or two later and this time I pulled straight down on the bulb to remove.  To my surprise the bulb came out, but at the ends of the bulb were 2 bare wires.  I had never seen this bulb in stores before.



Anyways here are some pictures I took of my fixture.  Can anyone tell me how I am to replace my busted bulbs?  Thanks!












      
I replaced a ceiling light with a fan/light with a remote. everthing works. their is one light switch and one dimmer switch. The dimmer switch has a red wire and a black wire connected to the black wires coming out of the dimmer switch, plus a green wire hooked to the metal portion of the dimmer. My question is: Do I have to remove the dimmer switch, if so, can I disconnect the red and black and hook them together? If I have to replace the dimmer with a regular switch, what kind of switch do I get?

Thank you